Anisotropy of the transverse mode ultrasonic properties of fixed tendon and fixed myocardium

被引:20
作者
Hoffmeister, BK [1 ]
Gehr, SE [1 ]
Miller, JG [1 ]
机构
[1] WASHINGTON UNIV, SCH MED, ST LOUIS, MO 63130 USA
关键词
D O I
10.1121/1.415000
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study investigates the influence of the fiber-reinforced nature of myocardium and tendon on the propagation of transverse mode ultrasonic waves. Formalin fixed specimens of normal human left ventricular cardiac muscle and bovine Achilles tendon were prepared for this study in such away that transverse mode ultrasonic waves could be propagated perpendicular to the fiber axis of the tissue with the polarization oriented either parallel or perpendicular to the fiber. axis. Measurements of velocity and attenuation were made at 3 MHz to assess the degree of anisotropy in these parameters for both tissues, Formalin fixed tendon exhibited a significant anisotropy whereas formalin fixed myocardium displayed a similar trend of more modest magnitude. Results of these measurements were used to compute two elastic stiffness coefficients for each tissue, yielding c(44) = 37.2 MPa and c(66) = 18.0 MPa for formalin fixed tendon, and c(44) = 8.97 MPa and c(66) = 8.45 MPa for formalin fixed myocardium. To-validate this approach, additional studies were conducted to measure the transverse mode ultrasonic properties of silicone rubber and motor oil. (C) 1996 Acoustical Society of America.
引用
收藏
页码:3826 / 3836
页数:11
相关论文
共 60 条
[1]  
ABRAHAMS C, 1987, LAB INVEST, V56, P676
[2]  
AMIEL D, 1988, COLLAGEN, V3, P223
[3]   INFLUENCE OF THE ORIENTATION OF MYOCARDIAL FIBERS ON ECHOCARDIOGRAPHIC IMAGES [J].
AYGEN, M ;
POPP, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (01) :147-152
[4]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P159, DOI 10.1016/0301-5629(79)90084-X
[5]   MYOCARDIAL ULTRASONIC BACKSCATTER FOR CHARACTERIZATION OF ISCHEMIA AND REPERFUSION - RELATIONSHIP TO WALL MOTION [J].
BARZILAI, B ;
VERED, Z ;
MOHR, GA ;
WEAR, KA ;
COURTOIS, M ;
SOBEL, BE ;
MILLER, JG ;
PEREZ, JE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (04) :391-398
[6]  
Barzilai B, 1988, J Am Soc Echocardiogr, V1, P179
[7]  
BAUWENS D, 1979, IN VIVO QUANTITATIVE, V59, P17
[8]  
BOLEF DI, 1971, PHYSICAL ACOUSTICS
[9]  
BORG TK, 1981, LAB INVEST, V44, P49
[10]   EFFECTS OF ANISOTROPY IN THE ULTRASONIC-ATTENUATION OF TISSUE ON COMPUTED-TOMOGRAPHY [J].
BRANDENBURGER, GH ;
KLEPPER, JR ;
MILLER, JB ;
SYNDER, DL .
ULTRASONIC IMAGING, 1981, 3 (02) :113-143