Comparison of low noise cooling performance of a Joule-Thomson cooler and a pulse-tube cooler using a HT SQUID

被引:13
作者
Hohmann, R [1 ]
Lienerth, C
Zhang, Y
Bousack, H
Thummes, G
Heiden, C
机构
[1] Res Ctr, Inst Thin Film & Ion Technol, Julich, Germany
[2] Univ Giessen, Inst Phys Appl, D-35390 Giessen, Germany
关键词
D O I
10.1109/77.783829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to their intrinsic low mechanical vibration level both, Joule-Thomson refrigerator and Pulse-Tube refrigerator are promising candidates for low noise cooling of high-T-c SQUIDs. We report here on a test comparing the performance of a commercial Joule-Thomson cooler and a single stage Pulse-Tube cooler used to operate one and the same HT rf SQUID under comparable conditions in shielded environment. In order to reduce vibrations the cold stages of both cooler systems were connected by flexible plastic lines of several meters length with their compressors. Operated in a liquid nitrogen cryostat, the white field noise of the SQUID was 40 fT/root Hz at frequencies above 30 Hz. A slightly higher white noise (about 60 fT/root Hz) was observed for operation with either of the two coolers. This is probably due to the vicinity of superinsulation to the SQUID. The Joule-Thomson cooler produced a somewhat higher low frequency excess noise below 30 Hz and some characteristic noise bands at intermediate frequencies (ca. 100 Hz - 500 Hz). The Pulse-Tube cooler led to a spectrum of lines at multiples of the pulse frequency (4.6 Hz). Both effects could be attributed (using cross correlation measurements) to residual mechanical vibrations of the cold heads of both coolers.
引用
收藏
页码:3688 / 3691
页数:4
相关论文
共 8 条
[1]   HTS SQUID system with Joule-Thomson cryocooler for eddy current nondestructive evaluation of aircraft structures [J].
Hohmann, R ;
Krause, HJ ;
Soltner, H ;
Zhang, Y ;
Copetti, CA ;
Bousack, H ;
Braginski, AI ;
Faley, MI .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :2860-2865
[2]  
HOHMANN R, UNPUB, P26703
[3]   COOLING OF HTSC JOSEPHSON-JUNCTIONS AND SQUIDS WITH CRYO-REFRIGERATORS [J].
KAISER, G ;
DORRER, L ;
MATTHES, A ;
SEIDEL, P ;
SCHMIDL, F ;
SCHNEIDEWIND, H ;
THURK, M .
CRYOGENICS, 1994, 34 :891-894
[4]   OPERATION OF BICRYSTAL JUNCTION HIGH-T-C DIRECT CURRENT-SQUID IN A PORTABLE MICROCOOLER [J].
KHARE, N ;
CHAUDHARI, P .
APPLIED PHYSICS LETTERS, 1994, 65 (18) :2353-2355
[5]  
RIJPMA AP, 1997, CRYOCOOLERS, V9, P727
[6]  
TERBRAKE HJM, 1997, CRYOCOOLERS, V9, P935
[7]  
Thummes G., 1997, Proceedings of the Sixteenth International Cryogenic Engineering Conference/International Cryogenic Materials Conference, P283, DOI 10.1016/B978-008042688-4/50066-1
[8]   Operation of high-sensitivity radio frequency superconducting quantum interference device magnetometers with superconducting coplanar resonators at 77 K [J].
Zhang, Y ;
Zander, W ;
Schubert, J ;
Ruders, F ;
Soltner, H ;
Banzet, M ;
Wolters, N ;
Zeng, XH ;
Braginski, AI .
APPLIED PHYSICS LETTERS, 1997, 71 (05) :704-706