Validity and reliability of palpation-digitization for non-invasive kinematic measurement - A systematic review

被引:25
作者
Adhia, Divya Bharatkumar [1 ,2 ]
Bussey, Melanie D. [1 ]
Ribeiro, Daniel Cury [2 ,3 ]
Tumilty, Steve [2 ]
Milosavljevic, Stephan [2 ]
机构
[1] Univ Otago, Sch Phys Educ, Dunedin, New Zealand
[2] Univ Otago, Ctr Physiotherapy Res, Dunedin, New Zealand
[3] Otago Polytech, Otago Inst Sport & Adventure, Dunedin, New Zealand
关键词
Validity; Reliability; Palpation-digitization; Kinematics; ANATOMICAL LANDMARK LOCATION; SPINAL PALPATION; CERVICAL RANGE; MOTION; SHOULDER; JOINT; BACK; IDENTIFICATION; VARIABILITY; DEVICE;
D O I
10.1016/j.math.2012.06.004
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
Joint kinematic assessment using an electromagnetic tracking device (EMTD) requires palpation-digitization (PD) of bony landmarks to define the anatomical axes. Errors in PD of bony landmarks can perturb the anatomical axes and affect the validity and reliability of kinematic measurements. The validity and reliability of PD for kinematic measurement needs to be explored before recommending its wider use. A systematic search of 15 electronic databases located studies assessing validity and/or reliability of PD for joint kinematic assessment. Two independent reviewers used the QUADAS and QAREL tools to assess quality of validity and reliability studies respectively. The results were synthesized qualitatively using a level of evidence approach. Eight studies satisfied the final eligibility criteria and were included in the review. The validity, intra-rater reliability and inter-rater reliability were assessed in three, seven and one study respectively. The overall level of evidence for validity of PD technique was strong with high correlation (>= 0.80) reported by three high (>= 60%) quality studies. The overall level of evidence for intra-rater reliability was also strong with very high ICC (>= 0.90) and satisfactory SEM (SEM % <= 10%) reported by four high quality studies. However the level of evidence for inter-rater reliability was limited and needs to be addressed by future research. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 44 条
[1]
APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]
Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: A comparison between an electromagnetic tracking system and an electronic inclinometer [J].
Assink, Nienke ;
Bergman, Gert J. D. ;
Knoester, Bianca ;
Winters, Jan C. ;
Dijkstra, Pieter U. .
MANUAL THERAPY, 2008, 13 (05) :450-455
[3]
Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[4]
Does blinding of readers affect the results of meta-analyses? [J].
Berlin, JA .
LANCET, 1997, 350 (9072) :185-186
[5]
A non-invasive technique for assessing innominate bone motion [J].
Bussey, MD ;
Yanai, T ;
Milburn, P .
CLINICAL BIOMECHANICS, 2004, 19 (01) :85-90
[6]
Culham E., 1993, CLIN REHABIL, V7, P309
[7]
The variability of shoulder motions recorded by means of palpation [J].
de Groot, JH .
CLINICAL BIOMECHANICS, 1997, 12 (7-8) :461-472
[8]
Human movement analysis using stereophotogrammetry - Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics [J].
Della Croce, U ;
Leardini, A ;
Chiari, L ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :226-237
[9]
Domholdt E, 2005, REHABILITATION RES P, P85
[10]
Effect of errors in the identification of anatomical landmarks on the accuracy of Q angle values [J].
France, L ;
Nester, C .
CLINICAL BIOMECHANICS, 2001, 16 (08) :710-713