New approaches in evaluating metallic candidates for bioabsorbable stents

被引:35
作者
Bowen, Patrick K. [1 ]
Drelich, Jaroslaw [1 ]
Buxbaum, Robert E. [2 ]
Rajachar, Rupak M. [3 ]
Goldman, Jeremy [3 ]
机构
[1] Michigan Technol Univ, Dept Mat Sci & Engn, Houghton, MI 49931 USA
[2] REB Res & Consulting, Oak Park, MI USA
[3] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
关键词
alloys; biomaterials; corrosion; metals; BIOMEDICAL MAGNESIUM ALLOY; RESORBABLE SUTURE MATERIAL; IN-VITRO CORROSION; CORONARY-STENT; ELUTING STENT; PURE IRON; BEHAVIOR; BIOCOMPATIBILITY; DEGRADATION; MG;
D O I
10.1680/emr.12.00017
中图分类号
T [工业技术];
学科分类号
120111 [工业工程];
摘要
A series of unconventional approaches has been developed at Michigan Technological University, which is able to screen candidate materials for use in bioabsorbable (or bioresorbable) stents by reducing the scale of necessary animal studies and the complexity of biocorrosion analyses. Using a novel in vivo approach, materials formed into a simplified wire geometry were implanted into the wall of the abdominal aorta of rodents for several weeks or months to measure the extent of in vivo degradation, quantify mechanical strength over time, characterize the resulting products, and assess biocompatibility. An in vitro method was developed to identify bioabsorbable candidate materials, reproduce the corrosion products formed in vivo, and predict the degradation rate of stent materials. To accomplish this goal, wires were encapsulated in an extracellular matrix and corroded in cell culture media in vitro. Encapsulation of the wires in vitro was necessary in order to mimic in vivo stent encapsulation within a neo-intima. Alternatively, accelerated in vitro corrosion for materials with very low corrosion rates was accomplished by exposing fibrin-coated wires to a steady flow of cell culture media. After in vivo and in vitro tests, wires were subjected to tensile testing to quantify the rate of material degradation and loss of mechanical strength.
引用
收藏
页码:237 / 255
页数:19
相关论文
共 76 条
[1]
Neuropathology of aluminum toxicity in rats (glutamate and GABA impairment) [J].
Abd El-Rahman, SS .
PHARMACOLOGICAL RESEARCH, 2003, 47 (03) :189-194
[2]
Corrosion mechanism applicable to biodegradable magnesium implants [J].
Atrens, Andrej ;
Liu, Ming ;
Abidin, Nor Ishida Zainal .
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2011, 176 (20) :1609-1636
[3]
Impact of the Everolimus-Eluting Stent on Stent Thrombosis A Meta-Analysis of 13 Randomized Trials [J].
Baber, Usman ;
Mehran, Roxana ;
Sharma, Samin K. ;
Brar, Somjot ;
Yu, Jennifer ;
Suh, Jung-Won ;
Kim, Hyo-Soo ;
Park, Seung-Jung ;
Kastrati, Adnan ;
de Waha, Antoinette ;
Krishnan, Prakash ;
Moreno, Pedro ;
Sweeny, Joseph ;
Kim, Michael C. ;
Suleman, Javed ;
Pyo, Robert ;
Wiley, Jose ;
Kovacic, Jason ;
Kini, Annapoorna S. ;
Dangas, George D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (15) :1569-1577
[4]
Dynamic shear stress in parallel-plate flow chambers [J].
Bacabac, RG ;
Smit, TH ;
Cowin, SC ;
Van Loon, JJWA ;
Nieuwstadt, FTM ;
Heethaar, R ;
Klein-Nulend, J .
JOURNAL OF BIOMECHANICS, 2005, 38 (01) :159-167
[5]
The corrosion of pure magnesium in aerated and deaerated sodium sulphate solutions [J].
Baril, G ;
Pébère, N .
CORROSION SCIENCE, 2001, 43 (03) :471-484
[6]
The Tensile Properties of Electrospun Nylon 6 Single Nanofibers [J].
Bazbouz, Mohamed Basel ;
Stylios, George K. .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2010, 48 (15) :1719-1731
[7]
Tensile testing as a novel method for quantitatively evaluating bioabsorbable material degradation [J].
Bowen, Patrick K. ;
Gelbaugh, Jesse A. ;
Mercier, Phillip J. ;
Goldman, Jeremy ;
Drelich, Jaroslaw .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (08) :2101-2113
[8]
Brandes EA., 2004, SMITHELLS METALS REF
[9]
Bünger CM, 2007, J ENDOVASC THER, V14, P725, DOI 10.1583/1545-1550(2007)14[725:ABSBOP]2.0.CO
[10]
2