Inferior Vena Cava Diameter (IVCD) Measured with Transesophageal Echocardiography (TEE) Can Be Used to Derive the Central Venous Pressure (CVP) in Anesthetized Mechanically Ventilated Patients

被引:39
作者
Arthur, Mary E. [1 ]
Landolfo, Carolyn [1 ,2 ]
Wade, Marlene [1 ]
Castresana, Manuel R. [1 ]
机构
[1] Med Coll Georgia, Dept Anesthesiol, Augusta, GA 30912 USA
[2] Med Coll Georgia, Dept Cardiol, Augusta, GA 30912 USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2009年 / 26卷 / 02期
关键词
central venous pressure (CVP); inferior vena cava diameter (IVCD); transesophageal echocardiography (TEE); RIGHT ATRIAL PRESSURE; ULTRASONOGRAPHY; FAILURE;
D O I
10.1111/j.1540-8175.2008.00772.x
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: Estimation of right atrial pressure (RAP) from variations in the diameter of the inferior vena cava (IVC) during the respiratory cycle using transthoracic echocardiography (TTE) is used routinely to calculate pulmonary artery systolic pressure, adding to right ventricular systolic pressure (RVSP) from the jet velocity of tricuspid regurgitation. Using transesophageal echocardiography (TEE) we sought to determine if the inferior vena cava diameter (IVCD) could be used to derive the central venous pressure (CVP) in anesthetized, mechanically ventilated patients. Methods: The IVCD was measured in its long axis (bicaval view) at the cavo-atrial junction using TEE and ECG synchronization (to coincide with the end of the T-wave) in 95 anesthetized, mechanically ventilated patients undergoing elective cardiac surgery. Each patient received a pulmonary artery catheter (PAC) that allowed for continuous monitoring of the CVP. Three independent readers were assigned to document the IVCD and the CVP. Statistical analysis was performed using bivariate correlation, variance (ANOVA), linear regression, Bland-Altman and Passing-Bablock analysis of agreement. Results: The IVCD measured in millimeters at the cavo-atrial junction showed a positive correlation with the CVP (n = 95, r = 0.860, P < 0.0001, r(2) = 0.737, P < 0.0001). The linear regression equation [CVPc = (IVCD-4.004/0.751] was prospectively tested in a cohort of 12 anesthetized, mechanically ventilated patients under various hemodynamic conditions with a good correlation between the mean CVP (CVPm) and the calculated CVP (CVPc) (r = 0.923, P < 0.0001, r(2) = 0.851, P < 0.0001). Conclusion: The TEE measured IVCD at the cavo-atrial junction showed a statistically significant correlation with the mean CVP. Using an equation derived from linear regression analysis, a reliable CVP can be estimated from the IVCD. (ECHOCARDIOGRAPHY, Volume 26, February 2009).
引用
收藏
页码:140 / 149
页数:10
相关论文
共 19 条
[1]
Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients [J].
Barbier, C ;
Loubières, Y ;
Schmit, C ;
Hayon, J ;
Ricôme, JL ;
Jardin, FO ;
Vieillard-Baron, A .
INTENSIVE CARE MEDICINE, 2004, 30 (09) :1740-1746
[2]
Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated [J].
Bendjelid, K ;
Romand, JA ;
Walder, B ;
Suter, PM ;
Fournier, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (09) :944-949
[3]
Update on echocardiography of the inferior vena cava [J].
D'Cruz, IA ;
Khouzam, RN .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (06) :543-545
[4]
Jue J, 1992, J Am Soc Echocardiogr, V5, P613
[5]
NONINVASIVE ESTIMATION OF RIGHT ATRIAL PRESSURE FROM THE INSPIRATORY COLLAPSE OF THE INFERIOR VENA-CAVA [J].
KIRCHER, BJ ;
HIMELMAN, RB ;
SCHILLER, NB .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (04) :493-496
[6]
Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis [J].
Krause, I ;
Birk, E ;
Davidovits, M ;
Cleper, R ;
Blieden, L ;
Pinhas, L ;
Gamzo, Z ;
Eisenstein, B .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (06) :1203-1206
[7]
Recommendations for chamber quantification: A report from the American Society of Echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology [J].
Lang, RM ;
Bierig, M ;
Devereux, RB ;
Flachskampf, FA ;
Foster, E ;
Pellikka, PA ;
Picard, MH ;
Roman, MJ ;
Seward, J ;
Shanewise, JS ;
Solomon, SD ;
Spencer, KT ;
Sutton, MS ;
Stewart, WJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1440-1463
[8]
Inferior vena cava diameter and central venous pressure correlation during cardiac surgery [J].
Lorsomradee, Suraphong ;
Lorsomradee, Sratwadee ;
Cromheecke, Stefanie ;
ten Broecke, Pieter W. ;
De Hert, Stefan G. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (04) :492-496
[9]
VENA-CAVA ULTRASONOGRAPHY FOR ASSESSING THE STATE OF HYDRATION OF PATIENTS IN RENAL-FAILURE [J].
MANDELBAUM, A ;
LINK, A ;
WAMBACH, G ;
RITZ, E .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1993, 118 (37) :1309-1315
[10]
MARK JB, 2005, REFR COURS LECT ASA