Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers

被引:77
作者
Hu, CH [1 ]
Xu, XC
Cannata, JM
Yen, JT
Shung, KK
机构
[1] Univ So Calif, Biomed Engn Dept, Los Angeles, CA 90089 USA
[2] Univ So Calif, NIH Transducer Resource Ctr, Los Angeles, CA 90089 USA
关键词
D O I
10.1109/TUFFC.2006.1593370
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A real-time digital beamformer for high-frequency (> 20 MHz) linear ultrasonic arrays has been developed. The system can handle up to 64-element linear array transducers and excite 16 channels and receive simultaneously at 100 MHz sampling frequency with 8-bit precision. Radio frequency (RF) signals are digitized, delayed, and summed through a real-time digital beamformer, which is implemented using a field programmable gate array (FPGA). Using fractional delay filters, fine delays as small as 2 ns can be implemented. A. frame rate of 30 frames per second is achieved. Wire phantom (20 mu m tungsten) images were obtained and -6 dB axial and lateral widths were measured. The results showed that, using a 30 MHz, 48-element array with a pitch of 100 mu m produced a -6 dB width of 68 mu m in the axial and 370 mu m in the lateral direction at 6.4 mm range. Images from an excised rabbit eye sample also were acquired, and fine anatomical structures, such as the cornea and lens, were resolved.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 28 条
[1]  
CANNATA JM, 2004, THESIS PENNSYLVANIA
[2]  
Cao PJ, 2003, ULTRASON, P1867
[3]  
Cao PJ, 2002, ULTRASON, P1619
[4]   PRINCIPLES AND APPLICATIONS OF ULTRASOUND BACKSCATTER MICROSCOPY [J].
FOSTER, FS ;
PAVLIN, CJ ;
LOCKWOOD, GR ;
RYAN, LK ;
HARASIEWICZ, KA ;
BERUBE, L ;
RAUTH, AM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :608-617
[5]   A new ultrasound instrument for in vivo microimaging of mice [J].
Foster, FS ;
Zhang, MY ;
Zhou, YQ ;
Liu, G ;
Mehi, J ;
Cherin, E ;
Harasiewicz, KA ;
Starkoski, BG ;
Zan, L ;
Knapik, DA ;
Adamson, SL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) :1165-1172
[6]  
Jensen JA, 1999, ULTRASON, P1595, DOI 10.1109/ULTSYM.1999.849300
[7]  
Laakso T.I., 1996, IEEE Signal Process. Mag, V13, P30, DOI [10.1109/79.482137, DOI 10.1109/79.482137]
[8]   Beyond 30 MHz - Applications of high-frequency ultrasound imaging [J].
Lockwood, GR ;
Turnbull, DH ;
Christopher, DA ;
Foster, FS .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :60-71
[9]   A COMPARISON OF EFFICIENT BEAMFORMING ALGORITHMS [J].
MUCCI, RA .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1984, 32 (03) :548-558
[10]  
ODONNELL M, 1990, ULTRASON, P1499, DOI 10.1109/ULTSYM.1990.171616