Effect of analyte adsorption on the electroosmotic flow in microfluidic channels

被引:60
作者
Ghosal, S [1 ]
机构
[1] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
关键词
D O I
10.1021/ac010571p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The predictability and constancy over time of the electroosmotic flow in microchannels is an important consideration in microfluidic devices. A common cause for alteration of the flow is the adsorption of analytes to channel walls, for example, during capillary electrophoresis of proteins. It is shown that certain experimental data, published by Towns and Regnier (Towns, J. K.; Regnier, F. E. Anal. Chem. 1992, 64, 2473-2478.), on the anomalous elution times for proteins in capillary electrophoresis can be explained using a simple model for analyte adsorption that uses a result first reported by Anderson and Idol (Anderson, J. L.; Idol, W. K. Chem. Eng. Commun. 1985, 38, 93-106.) on the electroosmotic flux in capillaries with axial variations in zeta-potential It is suggested that it might be possible to use such a model to dynamically correct for altered elution times in capillary electrophoretic devices.
引用
收藏
页码:771 / 775
页数:5
相关论文
共 16 条
  • [1] ELECTROOSMOSIS THROUGH PORES WITH NONUNIFORMLY CHARGED WALLS
    ANDERSON, JL
    IDOL, WK
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 1985, 38 (3-6) : 93 - 106
  • [2] WALL ADSORPTION IN CAPILLARY ELECTROPHORESIS - EXPERIMENTAL STUDY AND COMPUTER-SIMULATION
    ERMAKOV, SV
    ZHUKOV, MY
    CAPELLI, L
    RIGHETTI, PG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 699 (1-2) : 297 - 313
  • [3] DYNAMICS OF PEAK DISPERSION IN CAPILLARY ZONE ELECTROPHORESIS INCLUDING WALL ADSORPTION .1. THEORETICAL-MODEL AND RESULTS OF SIMULATION
    GAS, B
    STEDRY, M
    RIZZI, A
    KENNDLER, E
    [J]. ELECTROPHORESIS, 1995, 16 (06) : 958 - 967
  • [4] GHOSAL S, IN PRESS J FLUID MEC
  • [5] GHOSAL S, UNPUB PHYS FLUIDS
  • [6] Electroosmotic capillary flow with nonuniform zeta potential
    Herr, AE
    Molho, JI
    Santiago, JG
    Mungal, MG
    Kenny, TW
    Garguilo, MG
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (05) : 1053 - 1057
  • [7] REAL-TIME MEASUREMENT OF ELECTROOSMOTIC FLOW IN CAPILLARY ZONE ELECTROPHORESIS
    LEE, TT
    DADOO, R
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (17) : 2694 - 2700
  • [8] NASHABEH W, 1992, J HIGH RES CHROMATOG, V15, P289
  • [9] ELECTROOSMOSIS IN CAPILLARY ZONE ELECTROPHORESIS WITH NONUNIFORM ZETA-POTENTIAL
    POTOCEK, B
    GAS, B
    KENNDLER, E
    STEDRY, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (01) : 51 - 62
  • [10] Schaeper JP, 2000, ELECTROPHORESIS, V21, P1421