Feasibility and safety of ultrasound-aided thoracentesis in mechanically ventilated patients

被引:169
作者
Lichtenstein, D
Hulot, JS
Rabiller, A
Tostivint, I
Mezière, G
机构
[1] Hop Ambroise Pare, Serv Reanimat Med, F-92100 Boulogne, Paris, France
[2] Ctr Hosp Gen, Serv Reanimat Polyvalente, Paris, France
关键词
thoracentesis pleural effusion; ultrasound diagnosis; thorax; lung; intensive care unit;
D O I
10.1007/s001340050988
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Thoracentesis in a ventilated patient is rarely performed because of the risk of pneumothorax. We have evaluated the safety of this procedure when aided by ultrasound. Design: Prospective study. Setting: Medical intensive care unit, university-affiliated hospital. Patients: 45 procedures were performed in 40 consecutive patients with ultrasound signs of pleural effusion, all mechanically ventilated. Interventions: Pleural effusion was defined on ultrasound as a collection of fluid between parietal and visceral pleura leading to variations in interpleural distance during breathing. When the interpleural distance was greater than or equal to 15 mm and visible over three intercostal spaces, a needle (16 or 21 G) was inserted after ultrasound localization in a patient in either dorsal or lateral decubitus. Results: No complication occurred in the 45 thoracenteses. Fluid was obtained in 44 of 45 procedures, thus confirming the diagnosis of pleural effusion. The procedure was immediate (less than 10 s) in 40 of 45 cases. It was easy (i.e., keeping the patient supine) in 22 of 45 procedures. In 44 cases where fluid was obtained, only 27 bedside radiographs revealed signs of effusion, whereas 17 showed absence of a visible effusion. Ultrasound thus appeared more efficient than bedside X-ray in detecting pleural effusion. Conclusions: If basic rules are followed, ultrasound localization makes thoracentesis a safe, easy and simple procedure in patients on mechanical ventilation.
引用
收藏
页码:955 / 958
页数:4
相关论文
共 11 条
  • [1] THORACENTESIS - CLINICAL-VALUE, COMPLICATIONS, TECHNICAL PROBLEMS, AND PATIENT EXPERIENCE
    COLLINS, TR
    SAHN, SA
    [J]. CHEST, 1987, 91 (06) : 817 - 822
  • [2] QUANTIFICATION OF PLEURAL EFFUSIONS - SONOGRAPHY VERSUS RADIOGRAPHY
    EIBENBERGER, KL
    DOCK, WI
    AMMANN, ME
    DORFFNER, R
    HORMANN, MF
    GRABENWOGER, F
    [J]. RADIOLOGY, 1994, 191 (03) : 681 - 684
  • [3] THORACENTESIS - A SAFE PROCEDURE IN MECHANICALLY VENTILATED PATIENTS
    GODWIN, JE
    SAHN, SA
    [J]. ANNALS OF INTERNAL MEDICINE, 1990, 113 (10) : 800 - 802
  • [4] REFLECTED ULTRASOUND IN DETECTION AND LOCALIZATION OF PLEURAL EFFUSION
    JOYNER, CR
    HERMAN, RJ
    REID, JM
    [J]. JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 200 (05): : 399 - &
  • [5] Lichtenstein D, 1997, Rev Pneumol Clin, V53, P63
  • [6] INTENSIVE USE OF GENERAL ULTRASOUND IN THE INTENSIVE-CARE UNIT - PROSPECTIVE-STUDY OF 150 CONSECUTIVE PATIENTS
    LICHTENSTEIN, D
    AXLER, O
    [J]. INTENSIVE CARE MEDICINE, 1993, 19 (06) : 353 - 355
  • [7] LICHTENSTEIN D, 1992, ECHOGRAPHIE GEN REAN, P23
  • [8] A BEDSIDE ULTRASOUND SIGN RULING OUT PNEUMOTHORAX IN THE CRITICALLY ILL - LUNG SLIDING
    LICHTENSTEIN, DA
    MENU, Y
    [J]. CHEST, 1995, 108 (05) : 1345 - 1348
  • [9] OMOORE PV, 1987, AM J ROENTGENOL, V149, P1
  • [10] DETECTION OF PLEURAL EFFUSIONS ON SUPINE CHEST RADIOGRAPHS
    RUSKIN, JA
    GURNEY, JW
    THORSEN, MK
    GOODMAN, LR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (04) : 681 - 683