Fluence to effective dose and effective dose equivalent conversion coefficients for electrons from 5 MeV to 10 GeV

被引:29
作者
Ferrari, A
Pelliccioni, M
Pillon, M
机构
[1] INFN, Sezione di Milano, 20133 Milano
[2] INFN, Laboratori Nazionali di Frascati
[3] Assoc. EURATOM-ENEA sulla Fusione, Centro Ricerche Frascati, 00044 Frascati
关键词
D O I
10.1093/oxfordjournals.rpd.a031899
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose equivalent and effective dose per unit of fluence have been calculated using the FLUKA code for an anthropomorphic phantom placed in a vacuum and irradiated under Various geometrical conditions with electron beams. Calculations have been performed for monoenergetic electrons of energy ranging from 5 MeV to 10 GeV. Only relatively little information has been published up to now on effective dose and effective dose equivalent for electron irradiation. The agreement of the present values with the results of other authors, when existing, is generally satisfactory. A comparison of the results of the present calculations with the ambient dose equivalent shows that the operational quantity practically provides a conservative estimate of the limiting quantities up to about 30 MeV.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 16 条
[1]  
[Anonymous], P MC93 INT C MONT CA
[2]   Reference fluence-to-dose-equivalent conversion coefficients and angular dependence factors for 4-element ICRU tissue, water and PMMA slab phantoms irradiated by broad electron beams [J].
Chartier, JL ;
Grosswendt, B ;
Gualdrini, GF ;
Hirayama, H ;
Ma, CM ;
Padoani, F ;
Petoussi, N ;
Seltzer, SM ;
Terrissol, M .
RADIATION PROTECTION DOSIMETRY, 1996, 63 (01) :7-14
[3]  
CLARK M, 1996, NRPB B, V174
[4]  
FASSO A, 1995, IN PRESS P 2 WORKSH
[5]  
FERRARI A, 1994, RADIAT PROT DOSIM, V55, P207
[6]   Fluence to effective dose and effective dose equivalent conversion coefficients for photons from 50 keV to 10 GeV [J].
Ferrari, A ;
Pelliccioni, M ;
Pillon, M .
RADIATION PROTECTION DOSIMETRY, 1996, 67 (04) :245-251
[7]  
FERRARI A, 1994, RADIAT PROT DOSIM, V55, P309
[8]  
FERRARI A, 1994, P 8 INT C RAD SHIELD, V2, P893
[9]  
GROSSWENDT B, 1994, RADIAT PROT DOSIM, V54, P85
[10]   CALCULATION OF ABSORBED DOSE AT 0.07, 3.0 AND 10.0 MM DEPTHS IN A SLAB PHANTOM FOR MONOENERGETIC ELECTRONS [J].
HIRAYAMA, H .
RADIATION PROTECTION DOSIMETRY, 1994, 51 (02) :107-124