Determination of phenoxyacid herbicides and their phenolic metabolites in surface and drinking water

被引:36
作者
Marchese, S [1 ]
Perret, D [1 ]
Gentili, A [1 ]
D'Ascenzo, G [1 ]
Faberi, A [1 ]
机构
[1] Univ Roma La Sapienza, Dipartimento Chim, Lab Chim Sicurezza, I-00185 Rome, Italy
关键词
D O I
10.1002/rcm.557
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An evaluation was made of the feasibility of using reversed-phase liquid chromatography/tandem mass spectrometry with an electrospray interface (LC/ESI-MS/MS) to measure traces of phenoxyacid herbicides and their metabolites in surface and drinking water samples. The procedure involved passing 0.5 L of river and drinking water samples through a 0.5 g graphitized carbon black (GCB) extraction cartridge. Recovery was higher than 85% irrespective of the aqueous matrix in which the analytes were dissolved. A conventional 4.6-mm i.d. reversed-phase LC C-18 column operating with a mobile phase flow rate of 1 mL/min was used to chromatograph the analytes. A flow of 200 muL/min of the column effluent was diverted to the ESI source. The limits of detection (signal-to-noise ratio = 3) of the method for the pesticides considered in drinking and surface water samples are less than 0.1 ng/L for phenoxyacid herbicides, and about 5-10 ng/L for their metabolites (2,4-dichlorophenol and 4-chloro-2-methylphenol). Copyright (C) 2001 John Wiley Sons, Ltd.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 21 条
[1]   A review of sample storage and preservation of polar pesticides in water samples [J].
Barcelo, D ;
Alpendurada, MF .
CHROMATOGRAPHIA, 1996, 42 (11-12) :704-712
[2]  
BARCELO D, 1993, ENV ANAL TECHNIQUES, P149
[3]   Improved chromatographic method for the simultaneous determination of ten phenylurea herbicides and some of their degradation products in soil [J].
Berger, B .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :338-342
[4]   Trace determination of phenols in natural waters - Extraction by a new graphitized carbon black cartridge followed by liquid chromatography and re-analysis after phenol derivatization [J].
DiCorcia, A ;
Bellioni, A ;
Madbouly, MD ;
Marchese, S .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :383-393
[5]   EVALUATION OF GRAPHITIZED CARBON-BLACK AS A SELECTIVE ADSORBENT FOR EXTRACTING ACIDIC ORGANIC-COMPOUNDS FROM WATER [J].
DICORCIA, A ;
MARCHESE, S ;
SAMPERI, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :163-174
[6]   MULTIRESIDUE METHOD FOR PESTICIDES IN DRINKING-WATER USING A GRAPHITIZED CARBON-BLACK CARTRIDGE EXTRACTION AND LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
DICORCIA, A ;
MARCHETTI, M .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :580-585
[7]  
DICORCIA A, 1994, J AOAC INT, V77, pA446
[8]  
DICORCIA A, 1992, ENVIRON SCI TECHNOL, V26, P68
[9]   SURFACE-WATER ANALYSIS (TRACE-ORGANIC CONTAMINANTS) AND EC REGULATIONS [J].
HENNION, MC ;
PICHON, V ;
BARCELO, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :361-372
[10]   SPECIES-SELECTIVITY EFFECTS IN THE PRODUCTION OF ELECTROSPRAY IONS [J].
HIRAOKA, K ;
MURATA, K ;
KUDAKA, I .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (05) :363-373