Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation

被引:9
作者
Cooklin, M [1 ]
Tummala, RV [1 ]
Peters, RW [1 ]
Shorofsky, SR [1 ]
Gold, MR [1 ]
机构
[1] Univ Maryland, Sch Med, Div Cardiol, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0002-8703(99)70258-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Implantable cardioverter-defibrillation function is critically dependent on reliable sensing of intracordiac signals. Lead systems that use integrated sensing, in which the distal shocking coil is part of both the sensing and shocking pathways, may be prone to undersensing of ventricular fibrillation, especially during redetection after a failed first shock. To assess the effect of endocardial lead system on redetection, we compared a dedicated rate-sensing lead and 2 generations of integrated sensing defibrillator leads with a uniform testing algorithm and pulse generator. Methods The study group consisted of 72 patients when implantable cardioverier-defibrillator implatation. Three transvenous rate-sensing leads were evaluated: a standard pacing lead, incorporating true bipolar sensing without ventricular coils, or an integrated shocking and sensing lead (Endotak C) with either 6-mm (60 series) or 12-mm (70 series) spacing between the sensing tip and shocking coil. Redetection was assessed from a failed first shock lust below defibrillation threshold. Results Compared with the dedicated bipolar lead, redetection was prolonged with the 60 series lead (8.3 +/- 3.6 vs 6.6 +/- 2.3 seconds, P = .04). Moreover, prolonged redetection (>8 seconds) was observed in 41% of patients with 60 series leads compared with only 11% with dedicated bipolar leads (P < .01). No significant effects on redetection were noted with an integrated lead with greater spacing between the tip and coil (70 series). Conclusions Delayed redetection is frequently noted with an integrated lead with close spacing between the tip and coil. Detailed evaluation of detection and redetection of these leads should be performed at the time of pulse generator replacement.
引用
收藏
页码:133 / 136
页数:4
相关论文
共 18 条
[1]   ENSURING AUTOMATIC DETECTION OF VENTRICULAR-FIBRILLATION [J].
BARDY, GH .
CIRCULATION, 1992, 86 (05) :1634-1635
[2]   COMPARISON OF INITIAL DETECTION AND REDETECTION OF VENTRICULAR-FIBRILLATION IN A TRANSVENOUS DEFIBRILLATOR SYSTEM WITH AUTOMATIC GAIN-CONTROL [J].
BERUL, CI ;
CALLANS, DJ ;
SCHWARTZMAN, DS ;
PREMINGER, MW ;
GOTTLIEB, CD ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :431-436
[3]   APPROPRIATE SENSING OF VENTRICULAR-FIBRILLATION AFTER FAILED SHOCKS IN A TRANSVENOUS CARDIOVERTER-DEFIBRILLATOR SYSTEM [J].
ELLIS, JR ;
MARTIN, DT ;
VENDITTI, FJ .
CIRCULATION, 1994, 90 (04) :1820-1825
[4]   Transvenous defibrillation lead systems [J].
Gold, MR ;
Shorofsky, SR .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) :570-580
[5]  
GOLD MR, 1996, J AM COLL CARDIOL, V28, P1778
[6]   Improved sensing signals after endocardial defibrillation with a redesigned integrated sense pace defibrillation lead [J].
Isbruch, FM ;
Block, M ;
Bocker, D ;
Dees, H ;
Hammel, D ;
Borggrefe, M ;
Scheld, HH ;
Breithardt, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08) :1211-1218
[7]   FAILURE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR TO REDETECT VENTRICULAR-FIBRILLATION IN PATIENTS WITH A NONTHORACOTOMY LEAD SYSTEM [J].
JUNG, W ;
MANZ, M ;
MOOSDORF, R ;
LUDERITZ, B .
CIRCULATION, 1992, 86 (04) :1217-1222
[8]   Chronic rise in monophasic defibrillation thresholds with a transvenous lead system [J].
Kirk, MM ;
Shorofsky, SR ;
Khalighi, K ;
Kavesh, NG ;
Peters, RW ;
Gold, MR .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (04) :502-&
[9]   HYBRID NONTHORACOTOMY ICD SYSTEMS - LESSONS FROM THE BROUHAHA [J].
LEHMANN, MH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1802-1807
[10]   UNDERSENSING DURING VENTRICULAR TACHYARRHYTHMIAS IN A 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - DIAGNOSIS USING STORED ELECTROGRAMS AND CORRECTION WITH PROGRAMMING [J].
MANN, DE ;
KELLY, PA ;
DAMLE, RS ;
REITER, MJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (09) :1525-1530