Direct and rapid detection of diphtherotoxin via potentiometric immunosensor based on nanoparticles mixture and polyvinyl butyral as matrixes

被引:19
作者
Tang, DP [1 ]
Ren, JJ [1 ]
机构
[1] SW Univ, Coll Chem & Chem Engn, Chongqing 400715, Peoples R China
关键词
nanoparticles mixture; diphtherotoxin; direct and rapid detection; potentiometric immunosensor;
D O I
10.1002/elan.200503351
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper a novel potentiometric immunosensor for direct and rapid detection of diphtherotoxin (D-Ag) has been developed by means of self-assembly of monoclonal diphtheria antibody (D-Ab) onto a platinum electrode based on nanoparticles mixture (containing gold nanoparticles and silica nanoparticles) and polyvinyl butyral (PVB) as matrixes. At first, D-Ab was absorbed onto the surface of nanoparticles mixture, and then they were entrapped into polyvinyl butyral sol-gel network on a platinum electrode. The detection is based on the change in the potentiometric response before and after the antigen-antibody reaction in a phosphate buffer solution (pH 7.0). The immobilized D-Ab exhibited direct potentiometric response toward D-Ag. In comparison to the conventional applied methods, this strategy could allow antibodies immobilized with higher loading amount and better retained immunoactivity, as demonstrated by potentiometric response, cyclic voltammetry and electrochemical impedance spectroscopy of the immunosensor. The immunosensor with nanoparticles mixture exhibited much higher sensitivity, better reproducibility, and long-term stability than that with gold nanoparticles or silica nanoparticles alone. The linear range was from 5.0 x 10(-3) to 1.2 mu g (.) mL(-1) with a detection limit of 1.1 x 10(-3) mu g (.) mL(-1). Up to 16 successive assay cycles with retentive sensitivity were achieved for the probes regenerated with in 0.2 mol (.) L-1 glycine-hydrochloric acid (Gly-HCl) buffer solution and 0.25 mol (.) L-1 NaCl. Moreover, the immunosensor with nanoparticles mixture was applied to evaluate a number of practical specimens with potentiometric results in acceptable agreement with those given by the ELISA method, implying a promising alternative approach for detecting diphtherotoxin in the clinical diagnosis.
引用
收藏
页码:2208 / 2216
页数:9
相关论文
共 44 条
[1]   Detection of antigen-antibody binding events with the atomic force microscope [J].
Allen, S ;
Chen, XY ;
Davies, J ;
Davies, MC ;
Dawkes, AC ;
Edwards, JC ;
Roberts, CJ ;
Sefton, J ;
Tendler, SJB ;
Williams, PM .
BIOCHEMISTRY, 1997, 36 (24) :7457-7463
[2]  
[Anonymous], MOL IMMUNOLOGY
[3]   A glucose biosensor based on electrodeposited biocomposites of gold nanoparticles and glucose oxidase enzyme [J].
Bharathi, S ;
Nogami, M .
ANALYST, 2001, 126 (11) :1919-1922
[4]   POTENTIOMETRIC BIOSENSOR EMPLOYING CATALYTIC ANTIBODIES AS THE MOLECULAR RECOGNITION ELEMENT [J].
BLACKBURN, GF ;
TALLEY, DB ;
BOOTH, PM ;
DURFOR, CN ;
MARTIN, MT ;
NAPPER, AD ;
REES, AR .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2211-2216
[5]  
BLUM LJ, 1991, BIOSENSOR PRINCIPLES, P7
[6]   NUCLEIC-ACID DETECTION WITH SURFACE-PLASMON RESONANCE USING CATIONIC LATEX [J].
DEVRIES, EFA ;
SCHASFOORT, RBM ;
VANDERPLAS, J ;
GREVE, J .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (07) :509-514
[7]   Heterogeneous immunosensing using antigen and antibody monolayers on gold surfaces with electrochemical and scanning probe detection [J].
Dong, YZ ;
Shannon, C .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2371-2376
[8]   INVESTIGATION OF SPECIFIC BINDING OF ANTIFLUORESCYL ANTIBODY AND FAB TO FLUORESCEIN LIPIDS IN LANGMUIR-BLODGETT DEPOSITED FILMS USING QUARTZ-CRYSTAL MICROBALANCE METHODOLOGY [J].
EBATO, H ;
GENTRY, CA ;
HERRON, JN ;
MULLER, W ;
OKAHATA, Y ;
RINGSDORF, H ;
SUCI, PA .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1683-1689
[9]   COAGULATION OF COLLOIDAL GOLD [J].
ENUSTUN, BV ;
TURKEVICH, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1963, 85 (21) :3317-+
[10]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22