Review on physical and performance parameters of heat recovery systems for building applications

被引:35
作者
Mardiana, A. [1 ]
Riffat, S. B. [2 ]
机构
[1] Univ Sains Malaysia, Sch Ind Technol, Usm 11800, Pulau Pinang, Malaysia
[2] Univ Nottingham, Fac Engn, Dept Architecture & Built Environm, Nottingham NG7 2RD, England
关键词
Heat or energy recovery; Building applications; Physical parameters; Performance parameter; Efficiency; COUNTER-FLOW HEAT; MASS-TRANSFER; THERMAL PERFORMANCE; PRESSURE-DROP; AIR DEHUMIDIFICATION; VENTILATION SYSTEMS; ENTHALPY EXCHANGERS; ENERGY PERFORMANCE; TRIANGULAR DUCTS; LIQUID DESICCANT;
D O I
10.1016/j.rser.2013.07.016
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
Owing to global energy crisis, various technical strategies are adopted for energy conservation in buildings through energy-efficient technologies. One of the significant ways for this purpose is by installation or usage of heat or energy recovery device which is known as one of main energy-efficient systems that will decrease the power demands of building heating, cooling, air conditioning and ventilation loads. In order to have an insight into existing knowledge leading to understanding of previous works and researches carried out concerning the area, this paper presents and discusses physical and performance parameters of heat recovery unit and the significances of these parameters on operation and efficiency of the system. In addition, areas that have not received much research attention and that warrant future analysis of this technology are also highlighted. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:174 / 190
页数:17
相关论文
共 148 条
[1]
Heat pipe heat exchanger for heat recovery in air conditioning [J].
Abd El-Baky, Mostafa A. ;
Mohamed, Mousa M. .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :795-801
[2]
Plate heat exchangers: Recent advances [J].
Abu-Khader, Mazen M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (04) :1883-1891
[3]
Adamski M, 2010, ENERG BUILDINGS, V40, P1883
[4]
Ventilation system with spiral recuperator [J].
Adamski, Mariusz .
ENERGY AND BUILDINGS, 2010, 42 (05) :674-677
[5]
Ahmadi MS, 2009, INT J HEAT MASS TRAN, P6000
[6]
Ahmadzadehtalatapeh M, 2013, SCI IRANICA IN PRESS
[7]
CFD simulation of air to air enthalpy heat exchanger [J].
Al-Waked, Rafat ;
Nasif, Mohammad Shakir ;
Morrison, Graham ;
Behnia, Masud .
ENERGY CONVERSION AND MANAGEMENT, 2013, 74 :377-385
[8]
[Anonymous], 2001, HDB FUNDAMENTALS
[9]
A THEORETICAL CORRELATION FOR THE NUSSELT NUMBER IN DIRECT CONTACT EVAPORATION OF A MOVING DROP IN AN IMMISCIBLE LIQUID [J].
BATTYA, P ;
RAGHAVAN, VR ;
SEETHARAMU, KN .
WARME UND STOFFUBERTRAGUNG-THERMO AND FLUID DYNAMICS, 1985, 19 (01) :61-66
[10]
Can G, 1997, BUILD SERV ENG RES T, P67