A statistical analysis of the accuracy of sonography of the patellar tendon

被引:24
作者
Roberts, CS
King, DH
Goldsmith, LJ
机构
[1] Univ Louisville, Sch Med, Dept Orthopaed Surg, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Med, Ctr Biostat, Dept Informat Technol, Louisville, KY 40292 USA
来源
ARTHROSCOPY | 1999年 / 15卷 / 04期
关键词
sonography; correlation; agreement; accuracy; patellar tendon;
D O I
10.1016/S0749-8063(99)70056-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to evaluate the accuracy of sonography in measuring the dimensions of the cadaveric patellar tendon to determine whether sonography might have future applications in the preoperative assessment of autograft tissues before anterior cruciate ligament (ACL) reconstruction. Eleven lower-extremity human cadaveric limbs, with an average donor age of 75 years (range, 67 to 87 years), underwent patellar sonography with a 7.5-MHz transducer. Patellar tendon thickness, width, and length were measured sonographically. After skin removal, the patellar tendon dimensions were measured manually. Sonographic and manual measurements were compared statistically. Sonographic and manual measurements showed good agreement for thickness, There was poor agreement for width and length. Because of its limited accuracy, sonography cannot be recommended for the measurement of the patellar tendon before ACL reconstruction.
引用
收藏
页码:388 / 391
页数:4
相关论文
共 14 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   RUPTURE OF THE PATELLAR LIGAMENT AFTER USE OF ITS CENTRAL 3RD FOR ANTERIOR CRUCIATE RECONSTRUCTION - A REPORT OF 2 CASES [J].
BONAMO, JJ ;
KRINICK, RM ;
SPORN, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1294-1297
[3]   MAGNETIC-RESONANCE-IMAGING EVALUATION OF THE PATELLAR TENDON AFTER USE OF ITS CENTRAL ONE-THIRD FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
COUPENS, SD ;
YATES, CK ;
SHELDON, C ;
WARD, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (03) :332-335
[4]   SONOGRAPHY OF THE PATELLAR TENDON - PRELIMINARY-OBSERVATIONS [J].
FORNAGE, BD ;
RIFKIN, MD ;
TOUCHE, DH ;
SEGAL, PM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (01) :179-182
[5]  
Langan P, 1987, Orthop Rev, V16, P317
[6]  
LIEBER RL, 1994, ORTHOPAEDIC BASIC SC, P627
[7]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[8]   ASSAY VALIDATION USING THE CONCORDANCE CORRELATION-COEFFICIENT [J].
LIN, LIK .
BIOMETRICS, 1992, 48 (02) :599-604
[9]   Late patellar tendon ruptures after removal of the central third for anterior cruciate ligament reconstruction - A report of two cases [J].
Marumoto, JW ;
Mitsunaga, MM ;
Richardson, AB ;
Medoff, RJ ;
Mayfield, GW .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (05) :698-701
[10]  
MEISTERLING RC, 1993, CLIN ORTHOP RELAT R, P208