Automation of a plane grating spectrograph

被引:9
作者
Bellato, CR [1 ]
Rohwedder, JJR [1 ]
Raimundo, IM [1 ]
Pasquini, C [1 ]
机构
[1] UNIV ESTADUAL CAMPINAS,INST QUIM,BR-13083970 CAMPINAS,SP,BRAZIL
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1996年 / 18卷 / 01期
关键词
D O I
10.1155/S1463924696000028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A Zeiss model PGS-2 plane grating spectrograph was automated by replacing its photograph film detection system with an EGG-Reticon 1024S photodiode array (PDA) and by controlling the main instrument functions through the use of a home-made interface connected to a microcomputer. The array was cooled by four Peltier elements to allow integration of the emitted light for up to 40 s. The interface performs data acquisition from the sensor array, controls the grating position and the excitation source. A QuickBasic 4.5 program manages the interface, for data storage and treatment, and allows a graphical display and user-friendly interaction. Results show an absolute standard deviation for the wavelength localization of +/- 0.036 nm, and a spectral resolution of 0.05 nm at 443 nm when a 651 grooves/mm grating is employed. In each scan, the sensor array can collect data in a 18.7 nm wide window. Sensitivity was inferred from experimental data that showed an accurate localization of emission lines for Sn and Cu present in metal alloys at 0.006 and 0.03%, respectively. Quantitative results obtained for determination of Mn in steel samples and Ph in aqueous solution are also presented.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 25 条
[1]   APPLICATION OF A PHOTODIODE ARRAY DETECTOR TO AN ARC SPECTROGRAPH [J].
BRETT, L ;
STAHL, RG ;
TIMMINS, KJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :333-336
[2]  
BRETT L, 1991, ANAL P, V28, P224
[3]   ANALYTE MATRIX EXCITATION INVESTIGATIONS IN THE HIGH-VOLTAGE SPARK DISCHARGE USING AN ECHELLE CCD SYSTEM [J].
BYE, CA ;
SCHEELINE, A .
APPLIED SPECTROSCOPY, 1993, 47 (12) :2031-2035
[4]   SIMULTANEOUS MULTIELEMENT QUANTITATIVE SPECTROCHEMICAL ANALYSIS USING A DC ARC SOURCE AND A COMPUTER COUPLED PHOTODIODE ARRAY SPECTROMETER [J].
CODDING, EG ;
HORLICK, G .
SPECTROSCOPY LETTERS, 1974, 7 (01) :33-41
[5]   APPLICATION OF AND AND EXCLUSIVE-OR (XOR) LOGIC OPERATIONS TO IDENTIFICATION OF ELEMENTAL EMISSION-SPECTRA MEASURED USING A PHOTODIODE ARRAY DIRECT READING SPECTROMETER [J].
CODDING, EG ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1973, 27 (05) :366-370
[6]   AUTOMATED GRAVIMETRIC MANAGEMENT OF SOLUTIONS .1. HIGH-PERFORMANCE MICROCOMPUTER-CONTROLLED GRAVIMETRIC BURET [J].
CUNHA, IBS ;
PASQUINI, C .
ANALYST, 1992, 117 (05) :905-911
[7]   MULTISIGNAL CALIBRATION IN SPARK-OES AND ICP-OES [J].
DANZER, K ;
VENTH, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (06) :339-343
[8]   MULTISIGNAL CALIBRATION IN OPTICAL-EMISSION SPECTROSCOPY [J].
DANZER, K ;
WAGNER, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :520-524
[9]  
DANZER K, 1991, ACTA CHIM HUNG, V128, P623
[10]  
*EG G RET, 1992, OP AL PROC RC1000 10