Analysis of cardiac function by MRI and stereology

被引:24
作者
Roberts, N
CruzOrive, LM
Bourne, M
Herfkens, RJ
Karwoski, RA
Whitehouse, GH
机构
[1] UNIV CANTABRIA, FAC SCI, DEPT STAT & COMPUTAT MATH, E-39005 SANTANDER, SPAIN
[2] UNIV WALES COLL CARDIFF, NHS HLTH CARE TRUST, DEPT RADIOL, CARDIFF CF1 3NS, S GLAM, WALES
[3] STANFORD UNIV, DEPT DIAGNOST RADIOL, STANFORD, CA 94305 USA
[4] MAYO CLIN & MAYO FDN, DEPT PHYSIOL & BIOPHYS, ROCHESTER, MN 55905 USA
关键词
cardiology; Cavalieri method; heart; magnetic resonance imaging (MRI); point counting; stereology; systematic sampling; volume;
D O I
10.1046/j.1365-2818.1997.2040764.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Design-based stereology and phase contrast magnetic resonance imaging (MRI) were combined to monitor changes in the volume of the four chambers of the human heart during the cardiac cycle, The data set consisted of 18 adjacent slices (or 'scanning levels') of 0.5 cm thickness, perpendicular to the long axis of the body, and encompassing the whole heart of a healthy volunteer, At each scanning level, a cardiac gated MR image was obtained at each of 16 equally spaced time frames within the cardiac cycle. Given stationarity with respect to time, absence of image artefacts and appropriate definition of chamber boundaries, for each time frame unbiased estimates of total blood volume in the relevant heart chambers were efficiently obtained using the Cavalieri method and point counting, Combined with a proper MRI acquisition, modern stereological methods constitute an efficient and reliable tool to quantify cardiac function noninvasively.
引用
收藏
页码:31 / 42
页数:12
相关论文
共 35 条
[1]  
Cavalieri B, 1635, GEOMETRIA INDIVISIBI
[2]  
Cruz-Orive LM., 1993, B INT STAT I, V55, P451
[3]  
CRUZORIVE LM, 1987, J MICROSC-OXFORD, V145, P121
[4]   ON THE PRECISION OF SYSTEMATIC-SAMPLING - A REVIEW OF MATHERONS TRANSITIVE METHODS [J].
CRUZORIVE, LM .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :315-333
[5]   UNBIASED VOLUME ESTIMATION WITH COAXIAL SECTIONS - AN APPLICATION TO THE HUMAN BLADDER [J].
CRUZORIVE, LM ;
ROBERTS, N .
JOURNAL OF MICROSCOPY-OXFORD, 1993, 170 :25-33
[6]   ESTIMATION OF INDIVIDUAL FEATURE SURFACE-AREA WITH THE VERTICAL SPATIAL GRID [J].
CRUZORIVE, LM ;
HOWARD, CV .
JOURNAL OF MICROSCOPY-OXFORD, 1995, 178 :146-151
[7]   ESTIMATING THE LENGTH OF A BOUNDED CURVE IN 3 DIMENSIONS USING TOTAL VERTICAL PROJECTIONS [J].
CRUZORIVE, LM ;
HOWARD, CV .
JOURNAL OF MICROSCOPY-OXFORD, 1991, 163 :101-113
[8]   STEREOLOGY OF ARBITRARY PARTICLES - A REVIEW OF UNBIASED NUMBER AND SIZE ESTIMATORS AND THE PRESENTATION OF SOME NEW ONES, IN MEMORY OF THOMPSON,WILLIAM,R. [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1986, 143 :3-45
[9]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263
[10]   COMPARISON OF SEMIAUTOMATIC DIGITIZER-TABLET AND SIMPLE POINT COUNTING PERFORMANCE IN MORPHOMETRY [J].
GUNDERSEN, HJG ;
BOYSEN, M ;
REITH, A .
VIRCHOWS ARCHIV B-CELL PATHOLOGY INCLUDING MOLECULAR PATHOLOGY, 1981, 37 (03) :317-325