Comparison of corneal pachymetry using ultrasound and Orbscan II

被引:99
作者
Fakhry, MA
Artola, A
Belda, JL
Ayala, MJ
Alió, JL
机构
[1] Inst Oftalmol Alicante, Dept Refract Surg, Alicante 03015, Spain
[2] Inst Oftalmol Alicante, Dept Res & Dev, Alicante 03015, Spain
[3] Cairo Univ, Sch Med, Dept Ophthalmol, Cairo, Egypt
关键词
D O I
10.1016/S0886-3350(01)01277-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Orbscan II pachymetry with ultrasonic pachymetry in eyes having corneal refractive surgery. Settings: Instituto Oftalmologico de Alicante, Alicante, Spain. Methods: In this comparative prospective study, 72 eyes (36 patients) were divided into 4 groups: Group 1, 16 eyes with haze after photorefractive keratectomy (PRK) Group 2, 12 eyes with no haze after PRK; Group 3, 24 eyes that had uneventful laser in situ keratomileusis; Group 4, 20 normal eyes. The corneal thickness was measured in all eyes by the Orbscan 11 (version 3.27.10, Orbtek Inc.) and then by ultrasonic pachymetry (DHC 500, Technology Inc.). Results: The results between the 2 systems of pachymetry were significant in Group I (P <.0001) and not significant in Groups 2, 3, and 4 (P=.056, P=.051, and P=.68, respectively). A statistically significant correlation existed between the grade of haze and the decrease in Orbscan readings (C = -0.821, P <.0001). Conclusion. The Orbscan 11 pachymetry measurements correlated with the ultrasound measurements in eyes with clear corneas. Haze after PRK decreased the Orbscan pachymetry. J Cataract Refract Surg 2002; 28:248-252 (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:248 / 252
页数:5
相关论文
共 13 条
[1]  
Bovelle R, 1999, ARCH OPHTHALMOL-CHIC, V117, P868
[2]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[3]   VARIABILITY OF ULTRASONIC PACHOMETRY [J].
GORDON, A ;
BOGGESS, EA ;
MOLINARI, JF .
OPTOMETRY AND VISION SCIENCE, 1990, 67 (03) :162-165
[4]   INTERFEROMETRIC MEASUREMENT OF CORNEAL THICKNESS WITH MICROMETER PRECISION [J].
HITZENBERGER, CK ;
BAUMGARTNER, A ;
DREXLER, W ;
FERCHER, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (04) :468-476
[5]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[6]  
Lemp M A, 1985, Cornea, V4, P205
[7]   Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system [J].
Liu, ZG ;
Huang, AJ ;
Pflugfelder, SC .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (07) :774-778
[8]   Measurement of surgically induced corneal deformations using three-dimensional confocal microscopy [J].
Petroll, WM ;
Roy, P ;
Chuong, CJ ;
Hall, B ;
Cavanagh, HD ;
Jester, JV .
CORNEA, 1996, 15 (02) :154-164
[9]  
PROBST LEV, 1996, EXCIMER LASER REFRAC, P182
[10]  
REMON L, 1992, INVEST OPHTH VIS SCI, V33, P3080