Penalized-Likelihood Reconstruction for Metal Artifact Reduction in Cone-Beam CT

被引:8
作者
Aootaphao, Sorapong
Pintavirooj, Chuchart
Sotthivirat, Saowapak
机构
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4649767
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
CT reconstruction from metal-embedded data usually produces streak artifacts that reduce the quality of the reconstructed images. In this paper, we propose a new technique for metal artifact reduction in cone-beam CT based on statistical reconstruction. First, the metal objects are segmented in the reconstructed images and then reprojected to obtain the measurement data of the metal objects using cone-beam reconstruction. The original measurement data in the metal area are corrected through cubic interpolation. y, the corrected measurement data are reconstructed with the penalized likelihood using the modified convex algorithm. The simulation results show that the reconstructed images of the metal object using the proposed metal artifact reduction technique are superior to conventional filtered backprojection reconstruction.
引用
收藏
页码:2733 / 2736
页数:4
相关论文
共 8 条
[1]
AOOTAPHAO S, 2006, IEEE INT S COMM INF
[2]
Fessler J. A., 2000, Handb. Med. Imaging, V2, P1, DOI DOI 10.1117/3.831079
[3]
Huber P. J., 1981, ROBUST STAT
[4]
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI
[5]
Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm [J].
Kamphuis, C ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) :1101-1105
[6]
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[7]
YAZDI M, 2006, IEEE NUCL SCI S C
[8]
ZHAO S, 2000, IEEE T MED IMAGING, V19