Analysis of overlapped chromatographic peaks by multi-channel electrochemical detection

被引:5
作者
Cao, GM
Hoshino, T
机构
[1] Pharmaceutical Institute, School of Medicine, Keio University, Tokyo 160, 35 Shinano-Machi, Hinjuku-Ku
关键词
D O I
10.1016/0021-9673(95)00830-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative deconvolution of unresolved chromatographic peaks by multi-channel electrochemical detection was successfully performed. An electrochemical detector with four cells was employed. A regenerated current-voltage spectrum of three analyte components was obtained and used for peak deconvolution of the unresolved chromatographic peak. The overlapped peaks of three components, 5-hydroxyindole-3-acetic acid (5HIAA), deoxyepinephrine (DEP) and 3,4-dihydroxyhydrocinnamic acids (DHCA), was deconvoluted into the respective peaks of the components. The recoveries were 100.2% (5HIAA), 99.2% (DEP) and 99.7% (DHCA). This method could be used for the analysis of overlapped peaks in high-performance liquid chromatography with electrochemical detection.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 15 条
[1]   BIOGENIC-AMINES AND THEIR METABOLITES IN BODY-FLUIDS OF NORMAL, PSYCHIATRIC AND NEUROLOGICAL SUBJECTS [J].
DAVIS, BA .
JOURNAL OF CHROMATOGRAPHY, 1989, 466 :89-218
[2]   NOVEL TECHNIQUES FOR PEAK RECOGNITION AND DECONVOLUTION BY COMPUTER-AIDED PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :123-140
[3]   APPLICATIONS OF RAPID-SCANNING MULTICHANNEL DETECTORS IN CHROMATOGRAPHY - PLENARY LECTURE [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (01) :3-17
[4]   APPLICATION OF PHOTODIODE ARRAY ULTRAVIOLET DETECTOR TO UNRESOLVED PEAK ANALYSIS [J].
HOSHINO, T ;
SENDA, M ;
HONDO, T ;
SAITO, M ;
TOHEI, S .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :473-486
[5]   QUANTITATIVE DECONVOLUTION OF HEAVILY FUSED CHROMATOGRAPHIC PEAKS OF BIOLOGICAL COMPONENTS USING A MULTIWAVELENGTH UV DETECTOR [J].
HOSHINO, T ;
HONDO, T ;
SENDA, M ;
SAITO, M ;
TOHEI, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 332 (SEP) :139-146
[6]   SIMULTANEOUS MULTIWAVELENGTH DETECTION SYSTEM FOR LIQUID-CHROMATOGRAPHY [J].
KLATT, LN .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1979, 17 (04) :225-235
[7]  
LEE BL, 1989, J CHROMATOGR, V194, P303
[8]   MULTIPLE PEAK RECOGNITION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY FAST FOURIER TRANSFORMATION [J].
MALCZEWSKI, ML ;
GRUSHKA, E .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1981, 19 (04) :187-194
[9]  
MASHIGE F, 1993, JPN J CLIN CHEM, V22, P147
[10]   PERFORMANCE OF A SILICON TARGET VIDICON TUBE AS A MULTI-WAVELENGTH DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
MCDOWELL, AE ;
PARDUE, HL .
ANALYTICAL CHEMISTRY, 1977, 49 (08) :1171-1176