Specimen size and porosity can introduce error into μCT-based tissue mineral density measurements

被引:40
作者
Fajardo, Roberto J. [1 ,2 ]
Cory, Esther [1 ,2 ]
Patel, Nipun D. [1 ,2 ]
Nazarian, Ara [1 ,2 ]
Laib, Andres [3 ]
Manoharan, Rajaram K. [1 ,2 ,4 ]
Schmitz, James E. [1 ,2 ,4 ]
DeSilva, Jeremy M. [5 ]
MacLatchy, Laura M. [5 ]
Snyder, Brian D. [1 ,2 ,6 ]
Bouxsein, Mary L. [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Orthoped Biomech Lab, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Scanco Med AG, Bruettisellen, Switzerland
[4] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[5] Univ Michigan, Dept Anthropol, Ann Arbor, MI 48109 USA
[6] Childrens Hosp, Boston, MA 02115 USA
关键词
Bone tissue density; Specimen size; MicroCT; Beam-hardening correction; BEAM HARDENING CORRECTION; AGE-RELATED-CHANGES; TRABECULAR BONE; MICROCOMPUTED TOMOGRAPHY; QUANTITATIVE-DETERMINATION; GENETIC-VARIATION; SINGLE-ENERGY; FEMORAL-HEAD; LONG-TERM; ACCURACY;
D O I
10.1016/j.bone.2008.08.118
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The accurate measurement of tissue mineral density, rho(m), in specimens of unequal size or quantities of bone mineral using polychromatic mu CT systems is important, since studies often compare samples with a range of sizes and bone densities. We assessed the influence of object size on mu CT measurements of p using (1) hydroxyapatite rods (HA), (2) precision-manufactured aluminum foams (AL) simulating trabecular bone structure, and (3) bovine cortical bone cubes (Kt). Two beam-hardening correction (BHC) algorithms, determined using a 200 and 1200 mg/cm(3) HA wedge phantom, were used to calculate rho(m) of the HA and BCt. The 200 mg/cm3 and an aluminum BHC algorithm were used to calculate the linear attenuation coefficients of the AL foams. Equivalent (),, measurements of 500, 1000, and 1500 mg HA/cm(3) rods decreased (r(2)>0.96, p<0.05 for all) as HA rod diameter increased in the 200 mg/cm(3) BHC data. Errors averaged 8.2% across these samples and reached as high as 29.5%. Regression analyses Suggested no size effects in the 1200 mg/cm(3) BHC data but differences between successive sizes still reached as high as 13%. The linear attenuation coefficients of the AL foams increased up to approximately 6% with increasing volume fractions (r(2)>0.81, p<0.05 for all) but the strength of the size-related error was also BHC dependent. Equivalent pm values were inversely correlated with BCt Cube size (r(2)>0.92, p<0.05). Use of the 1200 mg/cm(3) BHC ameliorated the size-related artifact compared to the 200 mg/cm(3) BHC but errors with this BHC were still significant and ranged between 5% and 12%. These results demonstrate that object size, structure, and BHC algorithm can influence mu CT measurements of rho(m). Measurements of rho(m) of specimens of unequal size or quantities of bone mineral must be interpreted with caution unless appropriate steps are taken to minimize these potential artifacts. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:176 / 184
页数:9
相关论文
共 104 条
[1]
MEASUREMENT OF TRABECULAR BONE-MINERAL BY DUAL ENERGY COMPUTED-TOMOGRAPHY [J].
ADAMS, JE ;
CHEN, SZ ;
ADAMS, PH ;
ISHERWOOD, I .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (03) :601-607
[2]
Alterations in canine vertebral bone turnover, microdamage accumulation, and biomechanical properties following 1-year treatment with clinical treatment doses of risedronate or alendronate [J].
Allen, Matthew R. ;
Iwata, Ken ;
Phipps, Roger ;
Burr, David B. .
BONE, 2006, 39 (04) :872-879
[3]
Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[4]
DXA in vivo BMD methodology:: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility, and bone remodelling [J].
Bolotin, H. H. .
BONE, 2007, 41 (01) :138-154
[5]
Long-term risedronate treatment normalizes mineralization and continues to preserve trabecular architecture: Sequential triple biopsy studies with micro-computed tomography [J].
Borah, B ;
Dufresne, TE ;
Ritman, EL ;
Jorgensen, SM ;
Liu, S ;
Chmielewski, PA ;
Phipps, RJ ;
Zhou, XJ ;
Sibonga, JD ;
Turner, RT .
BONE, 2006, 39 (02) :345-352
[6]
Ovariectomy-induced bone loss varies among inbred strains of mice [J].
Bouxsein, ML ;
Myers, KS ;
Shultz, KL ;
Donahue, LR ;
Rosen, CJ ;
Beamer, WG .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (07) :1085-1092
[7]
BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[8]
PRECISE MEASUREMENT OF VERTEBRAL MINERAL-CONTENT USING COMPUTED-TOMOGRAPHY [J].
CANN, CE ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :493-500
[9]
LOW-DOSE CT SCANNING FOR QUANTITATIVE SPINAL MINERAL ANALYSIS [J].
CANN, CE .
RADIOLOGY, 1981, 140 (03) :813-815
[10]
CHASE R C, 1978, Medical Physics (Woodbury), V5, P497, DOI 10.1118/1.594486