Review of the performance of residential PV systems in France

被引:68
作者
Leloux, Jonathan [1 ]
Narvarte, Luis [1 ]
Trebosc, David [2 ]
机构
[1] ETSI Telecomunicac, Inst Energia Solar, Madrid 28040, Spain
[2] BDPV, F-31320 Castanet Tolosan, France
关键词
Residential PV system; Energy production; Performance Ratio; Performance Index; CIS; HIT; PI; France; MODULE;
D O I
10.1016/j.rser.2011.10.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main objective of this paper is to review the state of the art of residential PV systems in France. This is done analyzing the operational data of 6868 installations. Three main questions are posed. How much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? During the year 2010, the PV systems in France have produced a mean annual energy of 1163 kWh/kW(p). As a whole, the orientation of PV generators causes energy productions to be some 7% inferior to optimally oriented PV systems. The mean Performance Ratio is 76% and the mean Performance Index is 85%. That is to say, the energy produced by a typical PV system in France is 15% inferior to the energy produced by a very high quality PV system. On average, the real power of the PV modules falls 4.9% below its corresponding nominal power announced on the manufacturer's datasheet. A brief analysis by PV modules technology has led to relevant observations about two technologies in particular. On the one hand, the PV systems equipped with heterojunction with intrinsic thin layer (HIT) modules show performances higher than average. On the other hand, the systems equipped with the copper indium (di)selenide (CIS) modules show a real power that is 16% lower than their nominal value. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1369 / 1376
页数:8
相关论文
共 32 条
[1]  
[Anonymous], PVGIS
[2]  
Behnke Erdman Whitaker Engineering Inc, 2005, INTERIM EXPOSURE OPE
[3]  
Betts TR, 2003, WORL CON PHOTOVOLT E, P1756
[4]  
BLETTERIE B, 2007, E I ELEKTROTECHNIK I, V122, P349
[5]  
Caamaño E, 1999, PROG PHOTOVOLTAICS, V7, P137, DOI 10.1002/(SICI)1099-159X(199903/04)7:2<137::AID-PIP249>3.0.CO
[6]  
2-C
[7]  
Coello J., 2008, P 23 EUR PHOT SOL EN
[8]   Performance of 170 grid connected PV plants in northern Germany - Analysis of yields and optimization potentials [J].
Decker, B ;
Jahn, U .
SOLAR ENERGY, 1997, 59 (4-6) :127-133
[9]   The analysis on photovoltaic electricity generation status, potential and policies of the leading countries in solar energy [J].
Dincer, Furkan .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :713-720
[10]  
Erbs D., 1982, SOLAR ENERGY