Venous perforators in DIEAP flaps: An observational anatomical study using duplex ultrasonography

被引:22
作者
Figus, Andrea [1 ]
Wade, Ryckie G. [1 ]
Gorton, Louise [1 ]
Rubino, Corrado [2 ]
Griffiths, Matthew G. [1 ]
Ramakrishnan, Venkat V. [1 ]
机构
[1] St Andrews Ctr Plast Surg & Burns, Chelmsford, Essex, England
[2] Univ Sassari, Dept Plast Surg, I-07100 Sassari, Italy
关键词
Duplex; Perforator; Doppler; DIEAP; DIEP; SIEA; SIEV; Breast; Reconstruction; INFERIOR EPIGASTRIC PERFORATOR; ANTERIOR ABDOMINAL-WALL; FREE TRAM; HEMODYNAMIC-CHANGES; DOPPLER FLOWMETRY; ARTERY PERFORATOR; FLOW; RECONSTRUCTION; COMPLICATIONS; CONGESTION;
D O I
10.1016/j.bjps.2012.02.026
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background: The DIEAP flap has gained popularity for breast reconstruction worldwide. Despite DIEAP flap arterial anatomy being well known, venous congestion is still an important complication and the literature on DIEAP flap venous anatomy is lacking. Venous drainage is less predictable and research on venous perforators is of increasing interest. The aim of this study was to investigate the anatomical distribution, diameters and relationships between arterial and venous perforators and their source vessels using Duplex ultrasonography, in order to evaluate the potential benefits of pre-operative evaluation of DIEAP flap venous perforators. Methods: Prospectively, 140 patients undergoing DIEAP flap breast reconstruction, were pre-operatively assessed using Duplex ultrasonography for location and diameter of arterial and venous perforators, DIEA, DIEV, and SIEV. Perforators were plotted laterally and inferiorly from the umbilicus. Means were compared using t-tests. Pearson's correlation coefficients were calculated. Results: We identified 702 arterial and 355 venous perforators in 280 lower hemi-abdomens. No venous perforators were identified in 9 (6.5%) patients; none on the right in 25 (17.9%) and none on the left in 36 (25.7%). Venous perforators were larger on the right (p=0.031) but DIEV and SIEV diameters were not statistically different on either sides. The diameters of DIEA, DIEV, perforating arteries and veins were correlated, but unrelated to the diameter of the SIEV. When a medium/large perforator vein is identified first, there is a 93.5% chance of finding an associated medium/large perforator artery; this reduces to 69.8% when a medium/large perforator artery is first identified. Conclusions: There is no correlation between the sizes of perforator veins and DIEV, and the size of the SIEV. Our data suggests that first identifying a medium/large venous perforator increases the chances of finding a better suitable perforator complex. Pre-operative evaluation of venous perforators may be of great interest for its potential clinical benefits. (C) 2012 Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 40 条
[1]
Preoperative planning of deep inferior epigastric artery perforator flap reconstruction with multislice-CT angiography:: imaging findings and initial experience [J].
Alonso-Burgos, A. ;
Garcia-Tutor, E. ;
Bastarrika, G. ;
Cano, D. ;
Martinez-Cuesta, A. ;
Pina, L. J. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06) :585-593
[2]
Correlation between vessel diameters of superficial and deep inferior epigastric systems: Doppler ultrasound assessment [J].
Ayhan, Suehan ;
Oktar, Suna Ozhan ;
Tuncer, Serhan ;
Yucel, Cem ;
Kandal, Sebahattin ;
Demirtas, Yener .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2009, 62 (09) :1140-1147
[3]
Venous congestion and blood flow in free transverse rectus abdominis myocutaneous and deep inferior epigastric perforator flaps [J].
Blondeel, PN ;
Arnstein, M ;
Verstraete, K ;
Depuydt, K ;
Van Landuyt, KH ;
Monstrey, SJ ;
Kroll, SS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 106 (06) :1295-1299
[4]
Doppler flowmetry in the planning of perforator flaps [J].
Blondeel, PN ;
Beyens, G ;
Verhaeghe, R ;
Van Landuyt, K ;
Tonnard, P ;
Monstrey, SJ ;
Matton, G .
BRITISH JOURNAL OF PLASTIC SURGERY, 1998, 51 (03) :202-209
[5]
The deep inferior epigastric perforator flap for breast reconstruction., the learning curve explored [J].
Busic, V. ;
Das-Gupta, Rana ;
Mesic, H. ;
Begic, A. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06) :580-584
[6]
2-DIMENSIONAL COLOR DOPPLER IMAGING FOR PRECISION PREOPERATIVE MAPPING AND SIZE DETERMINATION OF TRAM FLAP PERFORATORS [J].
CHANG, BW ;
LUETHKE, R ;
BERG, WA ;
HAMPER, UM ;
MANSON, PN .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 93 (01) :197-200
[7]
COSTA MACE, 1987, PLAST RECONSTR SURG, V79, P208
[8]
The vascular anatomy of the lower anterior abdominal wall: A microdissection study on the deep inferior epigastric vessels and the perforator branches [J].
El-Mrakby, HH ;
Milner, RH .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 109 (02) :539-543
[9]
A SINGLE CENTER COMPARISON OF ONE VERSUS TWO VENOUS ANASTOMOSES IN 564 CONSECUTIVE DIEP FLAPS: INVESTIGATING THE EFFECT ON VENOUS CONGESTION AND FLAP SURVIVAL [J].
Enajat, Morteza ;
Rozen, Warren M. ;
Whitaker, Iain S. ;
Smit, Jeroen M. ;
Acosta, Rafael .
MICROSURGERY, 2010, 30 (03) :185-191
[10]
Comment on: Patel SA and Keller A 'A theoretical model describing arterial flow in the DIEP flap related to number and size of perforator vessels' J Plast Reconstr Aesthet Surg 2008;61:1316-20 [J].
Figus, Andrea ;
Ramakrishnan, Venkat ;
Rubino, Corrado .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (11) :1320-1320