Metal debris from titanium spinal implants

被引:88
作者
Wang, JC [1 ]
Yu, WD [1 ]
Sandhu, HS [1 ]
Betts, F [1 ]
Bhuta, S [1 ]
Delamarter, RB [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Orthopaed Surg, Los Angeles, CA 90095 USA
关键词
macrophage; metal particles; pseudarthrosis; spinal instrumentation; wear debris;
D O I
10.1097/00007632-199905010-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective study of tissue surrounding spinal instrumentation was performed using histologic and chemical analysis. Objectives. To identify and quantify the amount of metal debris generated by titanium pedicle screw instrumentation and to evaluate the histologic response in the spinal tissues. Summary of Background Data. Microscopic metal particles from the soft tissue surrounding joint arthroplasties have been shown to activate a macrophage response that leads to bone resorption and increased inflammation. The use of titanium spinal implants for spine surgery projects the possibility of generating wear debris in the spine. Methods. Nine patients with titanium instrumentation from a prior lumbar decompression and fusion procedure who were undergoing reoperation were entered into this study. Tissue samples were collected from areas near the pedicle screw-rod junction, the scar tissue overlying the dura, and the pedicle screw holes, Metal levels for titanium were determined by electrothermal atomic absorption spectroscopy, and histologic analysis was performed by light and electron microscopy. Results. Tissue concentrations of titanium were highest in patients with a pseudarthrosis (30.36 mu g/g of dry tissue). Patients with a solid fusion had low concentrations of titanium (0.586 mu g/g of dry tissue). Standard light microscopy identified metal particles in the soft tissues. Transmission electron microscopy demonstrated macrophages with numerous secondary lysosomes containing electron-dense bodies and collagenous stroma with electron-dense rod-like profiles consistent with metal debris. Conclusions, Wear debris is generated by the use of titanium spinal instrumentation in patients with a pseudarthrosis. These particles activate a macrophage cellular response in the spinal tissues similar to that seen in surrounding joint prostheses, Patients with a solid spinal fusion have negligible levels of particulate matter.
引用
收藏
页码:899 / 903
页数:5
相关论文
共 12 条
[1]  
[Anonymous], BIOMATER
[3]  
BETTS F, 1992, CLIN ORTHOPAEDICS, V26, P75
[4]  
HAYNES DR, 1997, 43 ANN M ORTH RES SO
[5]   ELECTRON-MICROSCOPIC OBSERVATIONS ON THE SOFT-TISSUE AROUND CLINICAL LONG-TERM PERCUTANEOUS TITANIUM IMPLANTS [J].
HOLGERS, KM ;
THOMSEN, P ;
TJELLSTROM, A ;
ERICSON, LE .
BIOMATERIALS, 1995, 16 (02) :83-90
[6]   Toward a biochemical understanding of human intervertebral disc degeneration and herniation - Contributions of nitric oxide, interleukins, prostaglandin E-2, and matrix metalloproteinases [J].
Kang, JD ;
StefanovicRacic, M ;
McIntyre, LA ;
Georgescu, HI ;
Evans, CH .
SPINE, 1997, 22 (10) :1065-1073
[7]   SIZE OF METALLIC AND POLYETHYLENE DEBRIS PARTICLES IN FAILED CEMENTED TOTAL HIP REPLACEMENTS [J].
LEE, JM ;
SALVATI, EA ;
BETTS, F ;
DICARLO, EF ;
DOTY, SB ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :380-384
[8]  
NAKASHIMA Y, 1997, 43 ANN M ORTH RES SO
[9]  
ORYSCHAK AF, 1974, VIRCHOWS ARCH B, V17, P159
[10]   IMPLANT-TISSUE INTERFACES FOLLOWING TREATMENT OF PERI-IMPLANTITIS USING GUIDED TISSUE REGENERATION - A LIGHT AND ELECTRON-MICROSCOPIC STUDY [J].
SCHUPBACH, P ;
HURZELER, M ;
GRUNDER, U .
CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (02) :55-65