Investigation on thermal performance of glazed solar chimney walls

被引:59
作者
Chantawong, P
Hirunlabh, J [1 ]
Zeghmati, B
Khedari, J
Teekasap, S
Win, MM
机构
[1] King Mongkuts Univ Technol, Bldg Sci Res Ctr, Sch Energy & Mat, Bangkok 10140, Thailand
[2] Univ Perpignan, Lab Mecan Acoust & Instrumentat, F-66860 Perpignan, France
[3] SE Asia Univ, Engn Management Program, Bangkok 10160, Thailand
关键词
heat gain reduction; indoor air ventilation; modeling; measurement;
D O I
10.1016/j.solener.2005.02.015
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reports investigation on the thermal performance of glazed solar chimney walls (GSCW) under the tropical climatic conditions of Thailand. The GSCW consisted of double glass panes with an air layer and openings located at the bottom (room side glass pane) and at the top (ambient side glass pane). A prototype of GSCW was integrated into the southern wall of a small room of 2.8 m(3) volume. Its dimensions were as follows: 0.74 m height, 0.50 m width and 0.10 m air gap. The size of openings was 0.05 x 0.5 m(2). With a clear glass of 6 mm thickness, velocity field measurement indicated that the induced airflow rate was about 0.13-0.28 m(3)/s. The temperature difference between room and ambient was less than that with a single layer clear glass window. The reduction of daylight due to the double glass layer A is negligible. Comparison between simulated and experimental results showed a reasonable agreement, therefore, the developed numerical model is valid and could be used as a tool for the design of GSCW. (c) 2005 Published by Elsevier Ltd.
引用
收藏
页码:288 / 297
页数:10
相关论文
共 25 条
[1]  
ALVAREZ G, 1989, P INT SOL EN C PART, P93
[2]  
ASHRAE, 2001, ASHRAE FUNDAMENTALS
[3]   SOLAR CHIMNEY FOR ENHANCED STACK VENTILATION [J].
BANSAL, NK ;
MATHUR, R ;
BHANDARI, MS .
BUILDING AND ENVIRONMENT, 1993, 28 (03) :373-377
[4]  
CHAPRA SC, 1990, NUMERICAL METHODS EN, P261
[5]   Daylight availability and models for global and diffuse horizontal illuminance and irradiance for Bangkok [J].
Chirarattananon, S ;
Chaiwiwatworakul, P ;
Pattanasethanon, S .
RENEWABLE ENERGY, 2002, 26 (01) :69-89
[6]  
FRABER EA, 1963, ASHRAE J AUG, P79
[7]   A numerical study of solar chimney for natural ventilation of buildings with heat recovery [J].
Gan, G ;
Riffat, SB .
APPLIED THERMAL ENGINEERING, 1998, 18 (12) :1171-1187
[8]   Thermal transmittance of multiple glazing: computational fluid dynamics prediction [J].
Gan, GH .
APPLIED THERMAL ENGINEERING, 2001, 21 (15) :1583-1592
[9]  
HADDAD KH, 1999, ASHRAE T, V4, P918
[10]  
HIRUNLABH J, 2002, J INT DHELIOTECHNIQU, P28