Combining standard addition method and second-order advantage for direct determination of salicylate in undiluted human plasma by spectrofluorimetry

被引:47
作者
Sena, MM [1 ]
Trevisan, MG [1 ]
Poppi, RJ [1 ]
机构
[1] Univ Estadual Campinas, Inst Chem, BR-13084971 Campinas, SP, Brazil
关键词
PARAFAC; salicylic acid; molecular fluorescence; SOSAM; blood;
D O I
10.1016/j.talanta.2005.08.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Second-order advantage turns possible a determination in the presence of unknown interferences. This work presented an application of the second-order advantage provided by parallel factor analysis (PARAFAC). The aim was the direct determination of salicylic acid (SA), the main product of aspirin degradation, in undiluted human plasma by spectrofluorimetry. The strategy of this analysis combined the use of PARAFAC, for extraction of the pure analyte signal, with the standard addition method, for a determination in the presence of a strong matrix effect caused by the quenching effect of the proteins present in the plasma. For each sample, four standard additions were performed, in niplicates. A specific PARAFAC model was built for each triplicate of each sample, from three-way arrays formed by 436 emission wavelengths, 7 excitation wavelengths and 5 measurements (sample plus 4 additions). In all the cases, the models were built with three factors and explained more than 99.90% of the total variance. The obtained loadings were related to SA and two background interferences. The scores related to SA were used for a linear regression in the standard addition method. Good results were obtained for determinations in the SA concentration range from 3.0 to 24.0 mu g ml(-1), providing errors of prediction between 0.7 and 6.3%. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1707 / 1712
页数:6
相关论文
共 41 条
[1]  
ABOUNASSIF MA, 1994, ANAL PROF DRUG SUBST, V23, P421
[2]   Practical aspects of PARAFAC modeling of fluorescence excitation-emission data [J].
Andersen, CM ;
Bro, R .
JOURNAL OF CHEMOMETRICS, 2003, 17 (04) :200-215
[3]   The N-way Toolbox for MATLAB [J].
Andersson, CA ;
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (01) :1-4
[4]  
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[5]  
[Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
[6]   First- and second-order multivariate calibration applied to biological samples: determination of anti-inflammatories in serum and urine [J].
Arancibia, JA ;
Olivieri, AC ;
Escandar, GM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :451-459
[7]   Two different strategies for the fluorimetric determination of piroxicam in serum [J].
Arancibia, JA ;
Escandar, GM .
TALANTA, 2003, 60 (06) :1113-1121
[9]   A 2ND-ORDER STANDARD ADDITION METHOD WITH APPLICATION TO CALIBRATION OF A KINETICS-SPECTROSCOPIC SENSOR FOR QUANTITATION OF TRICHLOROETHYLENE [J].
BOOKSH, K ;
HENSHAW, JM ;
BURGESS, LW ;
KOWALSKI, BR .
JOURNAL OF CHEMOMETRICS, 1995, 9 (04) :263-282
[10]   THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791