MultiSimplex and experimental design as chemometric tools to optimize a SPE-HPLC-UV method for the determination of eprosartan in human plasma samples

被引:36
作者
Ferreirós, N. [1 ]
Iriarte, G. [1 ]
Alonso, R. M. [1 ]
Jiménez, R. M. [1 ]
机构
[1] Univ Basque Country, EHU, Fac Ciencias & Tecnol, Dept Quim Analit, E-48080 Bilbao, Spain
关键词
eprosartan; human plasma; HPLC; SPE; multisimplex; experimental design;
D O I
10.1016/j.talanta.2005.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemometric approach was applied for the optimization of the extraction and separation of the anti hypertensive drug eprosartan from human plasma samples. MultiSimplex program was used to optimize the HPLC-UV method due to the number of experimental and response variables to be studied. The measured responses were the corrected area, the separation of eprosartan chromatographic peak from plasma interferences peaks and the retention time of the analyte. The use of an Atlantis dC18, 100 mm x 3.9 mm i.d. chromatographic column with a 0.026% trifluoroacetic acid (TEA) in the organic phase and 0.031% TEA in the aqueous phase, an initial composition of 80% aqueous phase in the mobile phase, a stepness of acetonitrile of 3% during the gradient elution mode with a flow rate of 1.25 mL/min and a column temperature of 35 +/- 0.2 degrees C allowed the separation of eprosartan and irbesartan used as internal standard from plasma endogenous compounds. In the solid phase extraction procedure, experimental design was used in order to achieve a maximum recovery percentage. Firstly, the significant variables were chosen by way of fractional factorial design; then, a central composite design was run to obtain the more adequate values of the significant variables. Thus, the extraction procedure for spiked human plasma samples was carried out using C8 cartridges, phosphate buffer pH 2 as conditioning agent, a drying step of 10 min, a washing step with methanol-phosphate buffer (20:80, v/v) and methanol as eluent liquid. The SPE-HPLC-UV developed method allowed the separation and quantitation of eprosartan from human plasma samples with an adequate resolution and a total analysis time of 1 h. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:747 / 756
页数:10
相关论文
共 33 条
[1]  
Atkinson A.C., 1992, OPTIMUM EXPT DESIGNS
[2]   Quantitative determination of the calcium channel antagonists amlodipine, lercanidipine, nitrendipine, felodipine, and lacidipine in human plasma using liquid chromatography-tandem mass spectrometry [J].
Baranda, AB ;
Mueller, CA ;
Alonso, RM ;
Jiménez, RM ;
Weinmann, W .
THERAPEUTIC DRUG MONITORING, 2005, 27 (01) :44-52
[3]  
BERGSTROEM J, 1998, MULTISIMPLEX 98
[4]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[5]   Experimental design methodologies to optimise the spectrofluorimetric determination of Losartan and Valsartan in human urine [J].
Cagigal, E ;
González, L ;
Alonso, RM ;
Jiménez, RM .
TALANTA, 2001, 54 (06) :1121-1133
[6]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[7]  
Deming SN., 1993, EXPT DESIGN CHEMOMET, DOI DOI 10.1016/j.plaphy.2010.08.016
[8]   Comparative study of the micellar enhanced spectrophotometric determination of β-lactamic antibiotics by batch and flow injection analysis using a multisimplex design [J].
Fernández-González, A ;
Badía, R ;
Díaz-García, ME .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (04) :669-679
[9]  
FERREIROS N, 2004, THESIS U BASQUE COUN
[10]  
González L, 2002, ELECTROPHORESIS, V23, P223, DOI 10.1002/1522-2683(200202)23:2<223::AID-ELPS223>3.0.CO