An immunosensor for haemoglobin based on impedimetric properties of a new mixed self-assembled monolayer

被引:26
作者
Hleli, S
Martelet, C [1 ]
Abdelghani, A
Bessueille, F
Errachid, A
Samitier, J
Hays, HCW
Millner, PA
Bums, N
Jaffrezic-Renault, N
机构
[1] CEGELY, Ctr Genie Elect Lyon, F-69134 Ecully, France
[2] IPEST, Unite Rech Phys Semicond & Capteurs, La Marsa, Tunisia
[3] Lab NanoBioEngn, Barcelona 08028, Spain
[4] Univ Leeds, Sch Biochem & Microbiol, Leeds LS2 9JT, W Yorkshire, England
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 2-3期
关键词
human haemoglobin; biotinyl-PE; neutravidin; mixed self-assembled monolayers; impedance spectroscopy; AFM; biosensors;
D O I
10.1016/j.msec.2005.10.054
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel impedimetric immunosensor for the detection of haemoglobin has been developed by mixed self-assembled monolayers on An. First, a mixed self-assembled monolayer (SAMs) consisting of 1,2 dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(biotinyl) (biotinyl-PE) and 16-mercaptobexadecanoic acid (MHDA) on gold electrodes was studied. The conformational properties of the SAMs were characterised by cyclic voltammetry and impedance spectroscopy. After blocking non-specific binding sites in the mixed monolayer using non-specific IgG, neutravidin was used to bind to biotinyl sites present in the mixed monolayer. Finally, biotinylated anti-haemoglobin IgG was immobilised to the tethered neutravidin. The membrane resistance R-m, obtained from the assembly, decreased gradually after the addition of non-specific IgG, neutravidin and anti-haemoglobin to the monolayer. This decrease could be attributed to a rearrangement in the structure of the SAMs. The detection of antibody-antigen reaction demonstrates that the potentiometric immunosensor exhibited high sensitivity and a detection limit of 20 ng/ml (approximately 0.3 nM). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 17 条
[1]  
[Anonymous], SUPRAMOL SCI
[2]   Sulfonated poly(ether ether sulfones) -: Characterization and study of dielectrical properties by impedance spectroscopy [J].
Benavente, J ;
García, JM ;
Riley, R ;
Lozano, AE ;
de Abajo, J .
JOURNAL OF MEMBRANE SCIENCE, 2000, 175 (01) :43-52
[3]   Probing direct binding affinity in electrochemical antibody-based sensors [J].
Corry, B ;
Uilk, J ;
Crawley, C .
ANALYTICA CHIMICA ACTA, 2003, 496 (1-2) :103-116
[4]   Assessing the apparent effective thickness of alkanethiol self-assembled monolayers in different concentrations of Fe(CN)63-/Fe(CN)64- by ac impedance spectroscopy [J].
Cui, XL ;
Jiang, DL ;
Diao, P ;
Li, JX ;
Tong, RT ;
Wang, XK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 470 (01) :9-13
[5]   Layer-by-layer assembly of multilayer films composed of avidin and biotin-labeled antibody for immunosensing [J].
Cui, XQ ;
Pei, RJ ;
Wang, XZ ;
Yang, F ;
Ma, Y ;
Dong, SJ ;
Yang, XR .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) :59-67
[6]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[7]   A correlation study between the conformation of the 1,4-dithiane SAM on gold and its performance to assess the heterogeneous electron-transfer reactions [J].
de Sousa, JR ;
Parente, MMV ;
Diógenes, LCN ;
Lopes, LGF ;
Neto, PD ;
Temperini, MLA ;
Batista, AA ;
Moreira, ID .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 566 (02) :443-449
[8]   Evaluation and origins of the difference between double-layer capacitance behaviour at Au-metal and oxidized Au surfaces [J].
Germain, PS ;
Pell, WG ;
Conway, BE .
ELECTROCHIMICA ACTA, 2004, 49 (11) :1775-1788
[9]   Colloidal gold as an electrochemical label of streptavidin-biotin interaction [J].
González-García, MB ;
Fernández-Sánchez, C ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :315-321
[10]   Impedance spectroscopy of self-assembled monolayers on Au(111): Sodium ferrocyanide charge transfer at modified electrodes [J].
Janek, RP ;
Fawcett, WR ;
Ulman, A .
LANGMUIR, 1998, 14 (11) :3011-3018