Stimulated acoustic emission to image a late liver and spleen-specific phase of Levovist® in normal volunteers and patients with and without liver disease

被引:91
作者
Blomley, MJK
Albrecht, T
Cosgrove, DO
Eckersley, RJ
Butler-Barnes, J
Jayaram, V
Patel, N
Heckemann, RA
Bauer, A
Schlief, R
机构
[1] Hammersmith Hosp, Dept Imaging, London W12 0HS, England
[2] Schering AG, D-1000 Berlin, Germany
关键词
ultrasound; contrast agents; microbubbles; liver; hepatic; pharmacokinetics; cirrhosis; attenuation;
D O I
10.1016/S0301-5629(99)00081-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitative studies were performed to investigate liver- specific uptake of the microbubble Levovist(R), using stimulated acoustic emission (SAE), which can detect microbubbles even when stationary or slow-moving. These comprised studies of biodistribution comparing the liver and kidney in five normal volunteers, reproducibility in 34 patients, comparison between cirrhotics and controls (n = 9 each) and maximal depth of effect at different frequencies (180 measurements in 31 patients). Stimulated acoustic emission lasted beyond 30 min, with strongly liver-specific properties in each volunteer and was highly reproducible. No difference in the amount of SAE in the superficial liver was seen between cirrhotic and normal livers, but attenuation was higher in cirrhotics, This demonstrates a frequency-dependent effect on liver SAE penetration. We conclude that the liver uptake of Levovist(R) lasts over 30 min, is reproducible, occurs even where diffuse liver disease is present and can be used to assess tissue attenuation in a novel fashion, (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1341 / 1352
页数:12
相关论文
共 15 条
  • [1] BAUER A, 1997, ADV ECHO IMAGING USI, P685
  • [2] BAUER A, 1997, ADV ECHO IMAGING USI, P669
  • [3] Stimulated acoustic emission in liver parenchyma with Levovist
    Blomley, M
    Albrecht, T
    Cosgrove, D
    Jayaram, V
    Butler-Barnes, J
    Eckersley, R
    [J]. LANCET, 1998, 351 (9102) : 568 - 568
  • [4] Stimulated acoustic emission imaging ("sono-scintigraphy") with the ultrasound contrast agent Levovist: A reproducible Doppler ultrasound effect with potential clinical utility
    Blomley, M
    Albrecht, T
    Cosgrove, D
    Jayaram, V
    Patel, N
    Butler-Barnes, J
    Eckersley, R
    Bauer, A
    Schlief, R
    [J]. ACADEMIC RADIOLOGY, 1998, 5 : S236 - S239
  • [5] Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience
    Blomley, MJK
    Albrecht, T
    Cosgrove, DO
    Patel, N
    Jayaram, V
    Butler-Barnes, J
    Eckersley, RJ
    Bauer, A
    Schlief, R
    [J]. RADIOLOGY, 1999, 210 (02) : 409 - 416
  • [6] BLOMLEY MJK, 1999, EUROP J RADIOL S1, V9, pS64
  • [7] Sound radiation of 3-MHz driven gas bubbles
    Grossmann, S
    Hilgenfeldt, S
    Lohse, D
    Zomack, M
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (02) : 1223 - 1230
  • [8] HINDLE AJ, 1995, BMUS MED B, P17
  • [9] KAMIYAM AN, 1996, RADIOLOGY, V201, P158
  • [10] Gray-scale second harmonic imaging of the liver with galactose-based microbubbles
    Kono, Y
    Moriyasu, F
    Mine, Y
    Nada, T
    Kamiyama, N
    Suginoshita, Y
    Matsumura, T
    Kobayashi, K
    Chiba, T
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (02) : 120 - 125