Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes

被引:428
作者
Finley, Charles C. [1 ,2 ]
Holden, Timothy A. [3 ]
Holden, Laura K. [3 ]
Whiting, Bruce R. [4 ]
Chole, Richard A. [3 ]
Neely, Gail J. [3 ]
Hullar, Timothy E. [3 ]
Skinner, Margaret W. [3 ]
机构
[1] Univ N Carolina, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] Washington Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
基金
美国国家卫生研究院;
关键词
Cochlear implantation; Computed tomography; Electrode placement; Insertion depth; Outcome variability; Scalar placement;
D O I
10.1097/MAO.0b013e318184f492
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: Suboptimal cochlear implant (CI) electrode array placement may reduce presentation of coded information to the central nervous system and, consequently, limit speech recognition. Background: Generally, mean speech reception scores for Cl recipients are similar across different CI systems, yet large outcome variation is observed among recipients implanted with the same device. These observations suggest significant recipient-dependent factors influence speech reception performance. This study examines electrode array insertion depth and scalar placement as recipient-dependent factors affecting outcome. Methods: Scalar location and depth of insertion of intracochlear electrodes were measured in 14 patients implanted with Advanced Bionics electrode arrays and whose word recognition scores varied broadly. Electrode position was measured using computed tomographic images of the cochlea and correlated with stable monosyllabic word recognition scores. Results: Electrode placement, primarily in terms of depth of insertion and scala tympani versus scala vestibuli location, varies widely across subjects. Lower outcome scores are associated with greater insertion depth and greater number of contacts being located in scala vestibuli. Three patterns of scalar placement are observed suggesting variability in insertion dynamics arising from surgical technique. C onclusion: A significant portion of variability in word recognition scores across a broad range of performance levels of Cl subjects is explained by variability in scalar location and insertion depth of the electrode array. We suggest that this variability in electrode placement can be reduced and average speech reception improved by better selection of cochleostomy sites, revised insertion approaches, and control of insertion depth during surgical placement of the array.
引用
收藏
页码:920 / 928
页数:9
相关论文
共 72 条
[1]   Evaluating cochlear implant trauma to the scala vestibuli [J].
Adunka, O ;
Kiefer, J ;
Unkelbach, MH ;
Radeloff, A ;
Gstoettner, W .
CLINICAL OTOLARYNGOLOGY, 2005, 30 (02) :121-127
[2]   Scala tympani cochleostomy I: Results of a survey [J].
Adunka, Oliver F. ;
Buchman, Craig A. .
LARYNGOSCOPE, 2007, 117 (12) :2187-2194
[3]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[4]   Quality control after insertion of the nucleus contour and contour advance electrode in adults [J].
Aschendorff, Antje ;
Kromeier, Jan ;
Klenzner, Thomas ;
Laszig, Roland .
EAR AND HEARING, 2007, 28 (02) :75S-79S
[5]   Nucleus multichannel cochlear implantation in partially ossified cochleas using the Steenerson procedure [J].
Bacciu, S ;
Bacciu, A ;
Pasanisi, E ;
Vincenti, V ;
Guida, M ;
Barbot, A ;
Berghenti, T .
OTOLOGY & NEUROTOLOGY, 2002, 23 (03) :341-345
[6]   Scala vestibuli cochlear implantation in patients with partially ossified cochleas [J].
Berrettini, S ;
Forli, F ;
Neri, E ;
Segnini, G ;
Franceschini, SS .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2002, 116 (11) :946-950
[7]  
Blamey P, 1996, Audiol Neurootol, V1, P293
[8]   The consequences of neural degeneration regarding optimal cochlear implant position in scala tympani: A model approach [J].
Briaire, Jeroen J. ;
Frijns, Johan H. M. .
HEARING RESEARCH, 2006, 214 (1-2) :17-27
[9]   Cochleostomy site: Implications for electrode placement and hearing preservation [J].
Briggs, RJS ;
Tykocinski, M ;
Stidham, K ;
Roberson, JB .
ACTA OTO-LARYNGOLOGICA, 2005, 125 (08) :870-876
[10]  
Briggs Robert J S, 2006, Audiol Neurootol, V11 Suppl 1, P42, DOI 10.1159/000095613