Improved workability of injectable calcium sulfate bone cement by regulation of self-setting properties

被引:66
作者
Chen, Zonggang [1 ,3 ]
Liu, Huanye [2 ]
Liu, Xi [3 ]
Lian, Xiaojie [4 ]
Guo, Zhongwu [1 ]
Jiang, Hong-Jiang [5 ]
Cui, Fu-Zhai [3 ]
机构
[1] Shandong Univ, Natl Glycoengn Res Ctr, Jinan 250100, Peoples R China
[2] China Med Univ, Sch Stomatol, Dept Orthodont, Shenyang 110001, Peoples R China
[3] Tsinghua Univ, Dept Mat Sci & Engn, Beijing 100084, Peoples R China
[4] Taiyuan Univ Technol, Coll Mech, Taiyuan 030024, Peoples R China
[5] Wendeng Hosp Tradit Chinese Orthoped & Traumatol, Wendeng 264400, Shandong, Peoples R China
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2013年 / 33卷 / 03期
基金
中国国家自然科学基金;
关键词
Injectable; Calcium sulfate; Bone cement; Self-setting property; Regulation; AUGMENTATION; DEFECTS; GRAFT; REGENERATION; HEMIHYDRATE; SUBSTITUTE; IMPLANT; PLASTER; SINUS;
D O I
10.1016/j.msec.2012.11.019
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
082905 [生物质能源与材料]; 100103 [病原生物学];
摘要
Calcium sulfate hemihydrate (CSH) powder as an injectable bone cement was prepared by hydrothermal synthesis of calcium sulfate dihydrate (CSD). The prepared materials showed X-ray diffraction peaks corresponding to the CSH structure without any secondary phases, implying complete conversion from CSD phase to CSH phase. Thermogravimetric (TG) analyses showed the crystal water content of CSH was about 6.0% (wt.), which is near to the theoretic crystal water value of CSH. From scanning electron microscopy (SEM) micrographs, sheet crystal structure of CSD was observed to transform into rod-like crystal structure of CSH. Most interesting and important of all, CSD as setting accelerator was also introduced into CSH powder to regulate self-setting properties of injectable CSH paste, and thus the self-setting time of CSH paste can be regulated from near 30 min to less than 5 min by adding various amounts of setting accelerator. Because CSD is not only the reactant of preparing CSH but also the final solidified product of CSH, the setting accelerator has no significant effect on the other properties of materials, such as mechanical properties. In vitro biocompatibility and in vivo histology studies have demonstrated that the materials have good biocompatibility and good efficacy in bone regeneration. All these will further improve the workability of CSH in clinic applications. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1048 / 1053
页数:6
相关论文
共 23 条
[1]
PLASTER - A BONE SUBSTITUTE [J].
BAHN, SL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1966, 21 (05) :672-+
[2]
Electrospun collagen-chitosan nanofiber: A biomimetic extracellular matrix for endothelial cell and smooth muscle cell [J].
Chen, Z. G. ;
Wang, P. W. ;
Wei, B. ;
Mo, X. M. ;
Cui, F. Z. .
ACTA BIOMATERIALIA, 2010, 6 (02) :372-382
[3]
COETZEE AS, 1980, ARCH OTOLARYNGOL, V106, P405
[4]
De Leonardis D, 1999, INT J ORAL MAX IMPL, V14, P869
[5]
Calcium sulphate-based cements containing cephalexin [J].
Doadrio, JC ;
Arcos, D ;
Cabañas, MV ;
Vallet-Regí, M .
BIOMATERIALS, 2004, 25 (13) :2629-2635
[6]
Self-setting properties and in vitro bioactivity of calcium sulfate hemihydrate-tricalcium silicate composite bone cements [J].
Huan, Zhiguang ;
Chang, Jiang .
ACTA BIOMATERIALIA, 2007, 3 (06) :952-960
[7]
Rapid Resorption of Calcium Sulfate and Hardware Failure Following Corrective Radius Osteotomy: 2 Case Reports [J].
Jepegnanam, Thilak S. ;
von Schroeder, Herbert P. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (03) :477-480
[8]
Effect of a calcium sulfate implant with calcium sulfate barrier on periodontal healing in 3-wall intrabony defects in dogs [J].
Kim, CK ;
Kim, HY ;
Chai, JK ;
Cho, KS ;
Moon, IS ;
Choi, SH ;
Sottosanti, JS ;
Wikesjö, UME .
JOURNAL OF PERIODONTOLOGY, 1998, 69 (09) :982-988
[9]
Grafting Using Injectable Calcium Sulfate in Bone Tumor Surgery: Comparison with Demineralized Bone Matrix-based Grafting [J].
Kim, June Hyuk ;
Oh, Joo Han ;
Han, Ilkyu ;
Kim, Han-Soo ;
Chung, Seok Won .
CLINICS IN ORTHOPEDIC SURGERY, 2011, 3 (03) :191-201
[10]
Extraction Socket Preservation Graft Before Implant Placement With Calcium Sulfate Hemihydrate and Platelet-Rich Plasma: A Clinical and Histomorphometric Study in Humans [J].
Kutkut, Ahmad ;
Andreana, Sebastiano ;
Kim, Hyeong-Il ;
Monaco, Edward, Jr. .
JOURNAL OF PERIODONTOLOGY, 2012, 83 (04) :401-409