Fast and accurate reference-free alignment of subtomograms

被引:57
作者
Chen, Yuxiang [1 ,2 ]
Pfeffer, Stefan [1 ]
Hrabe, Thomas [1 ]
Schuller, Jan Michael [1 ]
Foerster, Friedrich [1 ]
机构
[1] Max Planck Inst Biochem, Dept Mol Struct Biol, D-82152 Martinsried, Germany
[2] Tech Univ Munich, D-80290 Munich, Germany
关键词
Cryo-electron tomography; Subtomogram averaging; Spherical harmonics; 3-DIMENSIONAL STRUCTURE; IN-SITU; CRYOELECTRON TOMOGRAMS; ELECTRON TOMOGRAPHY; CLASSIFICATION; EM; MACROMOLECULES; ACQUISITION; TOOLBOX; IMAGES;
D O I
10.1016/j.jsb.2013.03.002
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
070307 [化学生物学]; 071010 [生物化学与分子生物学];
摘要
In cryoelectron tomography alignment and averaging of subtomograms, each dnepicting the same macromolecule, improves the resolution compared to the individual subtomogram. Major challenges of subtomogram alignment are noise enhancement due to overfitting, the bias of an initial reference in the iterative alignment process, and the computational cost of processing increasingly large amounts of data. Here, we propose an efficient and accurate alignment algorithm via a generalized convolution theorem, which allows computation of a constrained correlation function using spherical harmonics. This formulation increases computational speed of rotational matching dramatically compared to rotation search in Cartesian space without sacrificing accuracy in contrast to other spherical harmonic based approaches. Using this sampling method, a reference-free alignment procedure is proposed to tackle reference bias and overfitting, which also includes contrast transfer function correction by Wiener filtering. Application of the method to simulated data allowed us to obtain resolutions near the ground truth. For two experimental datasets, ribosomes from yeast lysate and purified 20S proteasomes, we achieved reconstructions of approximately 20 angstrom and 16 angstrom, respectively. The software is ready-to-use and made public to the community. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 52 条
[1]
Subtomogram alignment by adaptive Fourier coefficient thresholding [J].
Amat, Fernando ;
Comolli, Luis R. ;
Moussavi, Farshid ;
Smit, John ;
Downing, Kenneth H. ;
Horowitz, Mark .
JOURNAL OF STRUCTURAL BIOLOGY, 2010, 171 (03) :332-344
[2]
Classification and 3D averaging with missing wedge correction in biological electron tomography [J].
Bartesaghi, A. ;
Sprechmann, P. ;
Liu, J. ;
Randall, G. ;
Sapiro, G. ;
Subramaniam, S. .
JOURNAL OF STRUCTURAL BIOLOGY, 2008, 162 (03) :436-450
[3]
Membrane protein structure determination using cryo-electron tomography and 3D image averaging [J].
Bartesaghi, Alberto ;
Subramaniam, Sriram .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2009, 19 (04) :402-407
[4]
Beck M, 2009, NAT METHODS, V6, P817, DOI [10.1038/NMETH.1390, 10.1038/nmeth.1390]
[5]
Structure and assembly of immature HIV [J].
Briggs, J. A. G. ;
Riches, J. D. ;
Glass, B. ;
Bartonova, V. ;
Zanetti, G. ;
Kraeusslich, H.-G. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (27) :11090-11095
[6]
THE USE OF IN VITRO ASSAYS TO MEASURE ENDOPLASMIC RETICULUM-ASSOCIATED DEGRADATION [J].
Brodsky, Jeffrey L. .
METHODS IN ENZYMOLOGY, VOL 470: GUIDE TO YEAST GENETICS:: FUNCTIONAL GENOMICS, PROTEOMICS, AND OTHER SYSTEMS ANALYSIS, 2ND EDITION, 2010, 470 :661-679
[7]
Dynamo: A flexible, user-friendly development tool for subtomogram averaging of cryo-EM data in high-performance computing environments [J].
Castano-Diez, Daniel ;
Kudryashev, Mikhail ;
Arheit, Marcel ;
Stahlberg, Henning .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 178 (02) :139-151
[8]
Chen YX, 2012, 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), P1373, DOI 10.1109/ISBI.2012.6235823
[9]
RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY [J].
CROWTHER, RA ;
DEROSIER, DJ ;
KLUG, A .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530) :319-&
[10]
Unraveling the structure of membrane proteins in situ by transfer function corrected cryo-electron tomography [J].
Eibauer, Matthias ;
Hoffmann, Christian ;
Plitzko, Juergen M. ;
Baumeister, Wolfgang ;
Nickell, Stephan ;
Engelhardt, Harald .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 180 (03) :488-496