A Comparative Study of Five Reference Materials and the Lombard Meteorite for the Determination of the Platinum-Group Elements and Gold by LA-ICP-MS

被引:82
作者
Gilbert, Sarah [1 ]
Danyushevsky, Leonid [1 ]
Robinson, Philip [1 ]
Wohlgemuth-Ueberwasser, Cora [2 ]
Pearson, Norman [3 ]
Savard, Dany [4 ]
Norman, Marc [5 ]
Hanley, Jacob [6 ]
机构
[1] Univ Tasmania, CODES, Hobart, Tas 7001, Australia
[2] Univ Johannesburg, ZA-2006 Auckland Pk, South Africa
[3] Macquarie Univ, GEMOC, Sydney, NSW 2109, Australia
[4] Univ Quebec Chicoutimi, Chicoutimi, PQ G7H 2B1, Canada
[5] Australian Natl Univ, Canberra, ACT 0200, Australia
[6] St Marys Univ, Halifax, NS B3H 3C3, Canada
基金
澳大利亚研究理事会;
关键词
laser ablation; ICP-MS; platinum-group elements; gold; comparative study; NIS FIRE ASSAY; MASS SPECTROMETRY; MULTIELEMENT ANALYSIS; SIDEROPHILE ELEMENTS; ABLATION; BUTTONS; STANDARDS; MINERALS; NORILSK; GLASSES;
D O I
10.1111/j.1751-908X.2012.00170.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
070403 [天体物理学]; 070902 [地球化学];
摘要
A range of independently characterised reference materials (RMs) for LA-ICP-MS, used for the determination of the platinum-group elements (PGE) and Au in a sulfide matrix, were analysed and compared: 8b, PGE-A, NiS-3, Po727-T1, Po724-T and the Lombard meteorite. The newly developed RM NiS-3 was used as the RM for the calibration of all LA-ICP-MS analyses and the measured concentrations of the other RMs compared against their published concentrations. This data were also used to assess the consistency of concentrations calibrated against the different RMs. It was found that Po727-T1 and 8b produced results that were comparable, within uncertainty, for all elements. Po727-T1 also produced consistent results with NiS-3 for all elements. All other RMs showed differences for some elements, especially Ru in Po724-T, and Os, Ir and Au in PGE-A. The homogeneity of the PGE and Au in each RM was assessed, by comparing the precision of multiple LA-ICP-MS spot analyses with the average uncertainty of the signal. Po724-T, Po727-T1 and the Lombard meteorite were found to be homogeneous for all elements, but 8b, PGEA and NiS-3 were heterogeneous for some elements. This is the first direct comparison between a range of independently characterised PGE and Au LA-ICP-MS RMs.
引用
收藏
页码:51 / 64
页数:14
相关论文
共 29 条
[1]
Non-chondritic distribution of the highly siderophile elements in mantle sulphides [J].
Alard, O ;
Griffin, WL ;
Lorand, JP ;
Jackson, SE ;
O'Reilly, SY .
NATURE, 2000, 407 (6806) :891-894
[2]
Noble metal enrichment processes in the Merensky Reef, Bushveld Complex [J].
Ballhaus, C ;
Sylvester, P .
JOURNAL OF PETROLOGY, 2000, 41 (04) :545-561
[3]
The location of the chalcophile and siderophile elements in platinum-group element ore deposits (a textural, microbeam and whole rock geochemical study): Implications for the fort-nation of the deposits [J].
Barnes, Sarah-Jane ;
Prichard, Hazel M. ;
Cox, Richard A. ;
Fisher, Peter C. ;
Godel, Belinda .
CHEMICAL GEOLOGY, 2008, 248 (3-4) :295-317
[4]
Platinum-group element, gold, silver and base metal distribution in compositionally zoned sulfide droplets from the Medvezky Creek Mine, Noril'sk, Russia [J].
Barnes, Sarah-Jane ;
Cox, R. A. ;
Zientek, M. L. .
CONTRIBUTIONS TO MINERALOGY AND PETROLOGY, 2006, 152 (02) :187-200
[5]
Cabri L.J., 2010, P 42 ANN CAN MIN PRO, P181
[6]
Cabri L.J., 2005, 10 INT PLATINUM S PL, P16
[7]
Comparison of LAM-ICP-MS and micro-PIXE results for palladium and rhodium in selected samples of Noril'sk and Talnakh sulfides [J].
Cabri, LJ ;
Sylvester, PJ ;
Tubrett, MN ;
Peregoedova, A ;
Laflamme, JHG .
CANADIAN MINERALOGIST, 2003, 41 :321-329
[8]
Cox R.A., 2005, PLATINUM GROUP ELEME
[9]
Routine quantitative multi-element analysis of sulphide minerals by laser ablation ICP-MS: Standard development and consideration of matrix effects [J].
Danyushevsky, Leonid ;
Robinson, Phillip ;
Gilbert, Sarah ;
Norman, Marc ;
Large, Ross ;
McGoldrick, Peter ;
Shelley, Michael .
GEOCHEMISTRY-EXPLORATION ENVIRONMENT ANALYSIS, 2011, 11 (01) :51-60
[10]
NAA and UV laser ablation ICP-MS for platinum group elements and gold determination in NiS fire assay buttons: A comparison between two methods [J].
Figueiredo, AMG ;
Enzweiler, J ;
Sarkis, JES ;
Jorge, APS ;
Shibuya, EK .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (03) :623-625