Viscoelastic testing methodologies for tissue engineered blood vessels

被引:35
作者
Berglund, JD
Nerem, RM
Sambanis, A [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[2] Georgia Tech, Emory Ctr Engn Living Tissues, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 07期
关键词
tissue engineered blood vessels; viscoelastic testing; mathematical modeling; biomechanics;
D O I
10.1115/1.2073487
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In order to function in vivo, tissue engineered blood vessels (TEBVs) must encumber pulsatile blood flow and withstand hemodynamic pressures for long periods of time. To date TEBV mechanical assessment has typically relied on single time point burst and/or uniaxial tensile testing to gauge the strengths of the constructs. This study extends this analysis to include creep and stepwise stress relaxation viscoelastic testing methodologies. TEBV models exhibiting diverse mechanical behaviors as a result of different architectures ranging from reconstituted collagen gels to hybrid constructs reinforced with either untreated or glutaraldhyde-crosslinked collagen supports were evaluated after 8 and 23 days of in vitro culturing. Data were modeled using three and four-parameter linear viscoelastic mathematical representations and compared to porcine carotid arteries. While glutaraldhyde-treated hybrid TEBVs exhibited the largest overall strengths and toughness, uncrosslinked hybrid samples exhibited time-dependent behaviors most similar to native arteries. These findings emphasize the importance of viscoelastic characterization when evaluating the mechanical performance of TEBVs. Limits of testing methods and modeling systems are presented and discussed.
引用
收藏
页码:1176 / 1184
页数:9
相关论文
共 20 条
[1]   A biological hybrid model for collagen-based tissue engineered vascular constructs [J].
Berglund, JD ;
Mohseni, MM ;
Nerem, RM ;
Sambanis, A .
BIOMATERIALS, 2003, 24 (07) :1241-1254
[2]   Impaired carotid and femoral viscoelastic properties and elevated intima-media thickness in peripheral vascular disease [J].
Cheng, KS ;
Tiwari, A ;
Baker, CR ;
Morris, R ;
Hamilton, G ;
Seifalian, AM .
ATHEROSCLEROSIS, 2002, 164 (01) :113-120
[3]   BIAXIAL MECHANICS OF EXCISED CANINE PULMONARY-ARTERIES [J].
DEBES, JC ;
FUNG, YC .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (02) :H433-H442
[4]  
FUNG YC, 1993, BIOMECHANICS MECH PR, P222
[5]   Mechanisms of stiffening and strengthening in media-equivalents fabricated using glycation [J].
Girton, TS ;
Oegema, TR ;
Grassl, ED ;
Isenberg, BC ;
Tranquillo, RT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (03) :216-223
[6]  
Kanda K, 1993, ASAIO J, V39, pM561
[7]  
KIDSON IG, 1978, CIRCULATION, V58, P11
[8]   Rotational in vitro compliance measurement of diverse anastomotic configurations: a tool for anastomotic engineering [J].
Knez, P ;
Nelson, K ;
Hakimi, M ;
Al-Haidary, J ;
Schneider, C ;
Schmitz-Rixen, T .
JOURNAL OF BIOMECHANICS, 2004, 37 (03) :275-280
[9]   A completely biological tissue-engineered human blood vessel [J].
L'Heureux, N ;
Pâquet, S ;
Labbé, R ;
Germain, L ;
Auger, FA .
FASEB JOURNAL, 1998, 12 (01) :47-56
[10]   Impaired carotid viscoelastic properties in women with polycystic ovaries [J].
Lakhani, K ;
Seifalian, AM ;
Hardiman, P .
CIRCULATION, 2002, 106 (01) :81-85