Colonoscopy in mice

被引:37
作者
Huang, EH
Carter, JJ
Whelan, RL
Liu, YH
Rosenberg, JO
Rotterdam, H
Schmidt, AM
Stern, DM
Forde, KA
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Surg, New York, NY 10032 USA
[2] Columbia Univ, Coll Phys & Surg, Dept Adv Laparoscop Surg, New York, NY 10032 USA
[3] Columbia Univ, Coll Phys & Surg, Dept Pathol, New York, NY 10032 USA
[4] Columbia Univ, Coll Phys & Surg, Dept Med & Physiol, New York, NY 10032 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2002年 / 16卷 / 01期
关键词
mouse; murine; small animal; colonoscopy;
D O I
10.1007/s004640080168
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Current investigational models of murine colitis and colon cancer necessitate sacrifice of animals in order to obtain colonic tissue. The purpose of this study was to develop a safe method of murine colonoscopy that would allow serial evaluation and mucosal biopsies of the same animal. Methods: Nine mice (two C3H, two C57/BL6, and five IL-10 deficient) were studied a total of four times each over 4 weeks. Three mice [APC (Min +/-)] were examined three times each. Mice were gavaged with I cc of a polyethylene glycol solution on the day prior to colonoscopy. Solid chow was withheld and the mice were maintained on Pedialyte. Mice were anesthetized with ketamine and xylazine. A flexible pediatric cystoscope (2.1-mm diameter) with a single biopsy channel was introduced per anum, and the colon was gently insufflated with air to a mean pressure of less than 5 mmHg. Saline irrigation was used when necessary. A single biopsy was obtained from the rectosigmoid colon during each examination. Results: A total of 46 examinations were carried out. One mouse died after being anesthesized for the fourth examination, and two mice [one IL-10 knockout and one APC (Min)] died one day after the 3(rd) examination. No other complications were noted. The average length of insertion was 3 cm. Transillumination allowed for localization of the endoscope tip. Biopsies, although quite small, were sufficient for pathologic evaluation and diagnosis. Conclusions: Murine colonoscopy is a safe and feasible technique. It permits consecutive visual and histopathological examinations, and it allows the investigator to monitor the response of the murine colon to experimental interventions.
引用
收藏
页码:22 / 24
页数:3
相关论文
共 5 条
  • [1] INTERLEUKIN-10-DEFICIENT MICE DEVELOP CHRONIC ENTEROCOLITIS
    KUHN, R
    LOHLER, J
    RENNICK, D
    RAJEWSKY, K
    MULLER, W
    [J]. CELL, 1993, 75 (02) : 263 - 274
  • [2] A DOMINANT MUTATION THAT PREDISPOSES TO MULTIPLE INTESTINAL NEOPLASIA IN THE MOUSE
    MOSER, AR
    PITOT, HC
    DOVE, WF
    [J]. SCIENCE, 1990, 247 (4940) : 322 - 324
  • [3] Studies with IL-10(-/-) mice: An overview
    Rennick, DM
    Fort, MM
    Davidson, NJ
    [J]. JOURNAL OF LEUKOCYTE BIOLOGY, 1997, 61 (04) : 389 - 396
  • [4] Cytokines in inflammatory bowel disease
    Rogler, G
    Andus, T
    [J]. WORLD JOURNAL OF SURGERY, 1998, 22 (04) : 382 - 389
  • [5] MULTIPLE INTESTINAL NEOPLASIA CAUSED BY A MUTATION IN THE MURINE HOMOLOG OF THE APC GENE
    SU, LK
    KINZLER, KW
    VOGELSTEIN, B
    PREISINGER, AC
    MOSER, AR
    LUONGO, C
    GOULD, KA
    DOVE, WF
    [J]. SCIENCE, 1992, 256 (5057) : 668 - 670