GC-AED studies of nicotine fate in a burning cigarette

被引:19
作者
Stevens, NA [1 ]
Borgerding, MF [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Chem, Blacksburg, VA 24061 USA
关键词
D O I
10.1021/ac9900533
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An atomic emission detector (AED) for a gas chromatograph (GC) can be used to selectively detect compounds labeled with stable isotopes, such as D, C-13, and N-15. This capability can be used to determine precursor-fate relationships within complex matrices, using stable isotopes rather than radiolabeled isotopes. Employing stable isotopes removes the safety consideration associated with radiolabeling studies. Two previous reports have employed GC-AED in fate studies for C-13-labeled precursors. The goal of this study was to evaluate the utility of GC-AED for precursor-fate determinations in tobacco science; In this work, GC-AED was used to determine the fate of nicotine-d(4) in a burning cigarette. GC-MSD was then: employed to identify the compounds that the AED indicated contained D. Spectral confirmation of the presence of D was performed on each chromatographic peak of interest with both AED and MSD to ensure that the identification of the products was correct Nicotine and nicotine-de standards were used to evaluate the effect of coelution of unlabeled compounds with the labeled compounds on the AED response for D. It was shown that the AED response for D at lambda = 308 nm decreases with increased concentration of unlabeled compound. Detection at lambda = 656 nm, however, is unaffected by the presence of the unlabeled compound. Compound-independent calibration is also possible at this wavelength. GC-AED studies with nicotine-d(4) core injected into cigarettes demonstrated that most of the nicotine (79%) is distilled; unchanged, into the mainstream (MS) and sidestream (SS) smoke. The degradation products that do occur include 3-substituted pyridines and nicotine-oxidation products. These are found only in the SS smoke.
引用
收藏
页码:2179 / 2185
页数:7
相关论文
共 12 条
[1]   DETECTION OF C-13 LABELED COMPOUNDS BY GAS-CHROMATOGRAPHY COUPLED TO ATOMIC-EMISSION DETECTION-APPLICATION TO CAFFEINE METABOLITES [J].
BOUKRAA, MS ;
DERUAZ, D ;
BANNIER, A ;
DESAGE, M ;
BRAZIER, JL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (02) :185-194
[2]   SELECTIVE DETECTION OF C-13, N-15, AND DEUTERIUM LABELED METABOLITES BY CAPILLARY GAS-CHROMATOGRAPHY CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
CHACE, DH ;
ABRAMSON, FP .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2724-2730
[3]  
Houseman TH, 1973, BEITR TABAKFORSCH, V7, P142
[4]  
JENKINS RW, 1977, BEITR TABAKFORSCH, V9, P126
[5]   A REVIEW OF THE USES OF NUCLEAR RADIATION IN TOBACCO AND SMOKE RESEARCH [J].
JENKINS, RW .
BEITRAGE ZUR TABAKFORSCHUNG INTERNATIONAL, 1990, 14 (06) :353-378
[6]  
Oshita K., 1995, P 25 EUR BREW CONV C, P387
[7]  
QUIMBY BD, 1991, SYNTH APL ISOT LABEL, P128
[8]  
REYNOLDS RJ, 1988, NEW CIGARETTE PROTO, P156
[9]  
SCMELZ I, 1979, J AGR FOOD CHEM, V27, P602
[10]   IMPROVED STABLE NITROGEN ISOTOPE RATIO MEASUREMENTS OF NATURAL GASES [J].
SOHNS, E ;
GERLING, P ;
FABER, E .
ANALYTICAL CHEMISTRY, 1994, 66 (17) :2614-2620