STEAM-Burst: A single-shot, multi-slice imaging sequence without rapid gradient switching

被引:11
作者
Cremillieux, Y
WheelerKingshott, CA
Briguet, A
Doran, SJ
机构
[1] UNIV SURREY, DEPT PHYS, GUILDFORD GU2 5XH, SURREY, ENGLAND
[2] UCB, LAB RMN, LYON, FRANCE
关键词
3D imaging; ultra-fast imaging; Burst; STEAM;
D O I
10.1002/mrm.1910380419
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The stimulated-echo acquisition mode-Burst sequence is a single-shot, multi-slice imaging technique that does not involve rapid gradient switching. A Burst excitation pulse train is followed by a 90 degrees hard pulse and, after a mixing time, by a 90 degrees slice-selective pulse, A read gradient refocuses a set of stimulated echoes, which can be phase-encoded to form an image. By repeating the selective pulse N times, each time with the carrier frequency offset differently, it is possible to sample N slices in a single-shot, A comparison is made of the sequence with other three-dimensional single-shot methods, Experiments implementing the technique on a 3 T whole-body imaging system and a 2 T, 31-cm bore animal imager are described. Both phantom and brain images are presented, The principal advantages of the new sequence are its speed, the absence of rapid gradient switching and corresponding freedom from artifacts, its insensitivity to static magnetic field inhomogeneities, and its low acoustic noise, The main disadvantages are the low signal-to-noise ratio of the images produced and the concomitant limitation in resolution.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 21 条
  • [1] CREMILLIEUX Y, 1996, P SMRM 4 ANN NEW YOR, P1500
  • [2] A robust, single-shot method for measuring diffusion coefficients using the ''Burst'' sequence
    Doran, SJ
    Decorps, M
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 117 (02) : 311 - 316
  • [3] 3D BOLUS TRACKING WITH FREQUENCY-SHIFTED BURST MRI
    DUYN, JH
    VANGELDEREN, P
    BARKER, P
    FRANK, JA
    MATTAY, VS
    MOONEN, CTW
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (05) : 680 - 687
  • [4] FAST VOLUME SCANNING WITH FREQUENCY-SHIFTED BURST MRI
    DUYN, JH
    VANGELDEREN, P
    LIU, GY
    MOONEN, CTW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 429 - 432
  • [5] STIMULATED ECHO IMAGING
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    HAASE, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) : 81 - 93
  • [6] FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES
    HAASE, A
    FRAHM, J
    MATTHAEI, D
    HANICKE, W
    MERBOLDT, KD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) : 258 - 266
  • [7] Echo-volumar imaging (EVI) at 0.5 T: First whole-body volunteer studies
    Harvey, PR
    Mansfield, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 80 - 88
  • [8] ULTRA-RAPID GRADIENT-ECHO IMAGING
    HEID, O
    DEIMLING, M
    HUK, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 143 - 149
  • [9] HEID O, 1995, P SMRM 3 ANN M NIC, P98
  • [10] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833