Paracorporeal pulsatile biventricular assist device versus extracorporal membrane oxygenation-extracorporal life support in adult fulminant myocarditis

被引:63
作者
Pages, Olivier N. [1 ]
Aubert, Stephane [1 ]
Combes, Alain [2 ]
Luyt, Charles E. [2 ]
Pavie, Alain [1 ]
Leger, Philippe [3 ]
Gandjbakhch, Iradj [1 ]
Leprince, Pascal [1 ]
机构
[1] Univ Paris 06, Serv Chirurg Thorac & Cardiovascu, Grp Pitie Salpetriere, Inst Cardiol,AP HP, F-75013 Paris, France
[2] Univ Paris 06, Serv Reanimat Med, Grp Pitie Salpetriere, Inst Cardiol,AP HP, F-75013 Paris, France
[3] Univ Paris 06, Dept Anesthesie Reanimat, Grp Pitie Salpetriere, AP HP, F-75013 Paris, France
关键词
MECHANICAL CIRCULATORY SUPPORT; RECOVERY; SHOCK;
D O I
10.1016/j.jtcvs.2008.09.051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Biventricular assist device support with a paracorporeal pulsatile device is known to be an efficient bridge to recovery for patients with fulminant myocarditis-related cardiogenic shock. Whether these patients can be as efficiently supported with femorofemoral extracorporeal membrane oxygenation remains unclear. Methods: From 2001 to 2006, 11 patients were referred to our cardiac surgery department for fulminant myocarditis-related cardiogenic shock. The first 5 patients (mean age, 32 +/- 2 years) were supported with a biventricular assist device (Thoratec, Pleasanton, Calif; group I), whereas the remaining patients ( 40 +/- 4 years) were supported with femorofemoral extracorporeal membrane oxygenation (group II). Preimplantation probability of death was calculated by using the APACHE II score, which was 11 +/- 9 in group I versus 24 +/- 18 in group II. Results: One patient in each group died while receiving support. In group I the death occurred after 18 days of support in a patient who had 45 minutes of external resuscitation before biventricular assist device implantation. In group II a patient who remained unstable during extracorporeal membrane oxygenation was switched to a biventricular assist device 13 days later and eventually died of tamponade after 45 days. All other patients were weaned from the device after a mean duration of support of 21 +/- 5 days in group I versus 13 +/- 4 days in group II. At hospital discharge, the mean ejection fraction was 45% +/- 5% in both groups, and at 6 months' follow-up, it was 65% and 75%, respectively, in groups I and II. Conclusion: In our experience extracorporeal membrane oxygenation is as efficient as use of a biventricular assist device as a bridge to recovery for patients with fulminant myocarditis-related cardiogenic shock and facilitates renal and hepatic recovery on support.
引用
收藏
页码:194 / 197
页数:4
相关论文
共 9 条
[1]   Mechanical circulatory support for patients with acute-fulminant myocarditis [J].
Acker, MA .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S73-S76
[2]   Experience and result of extracorporeal membrane oxygenation in treating fulminant myocarditiis with shock: What mechanical support should be considered first? [J].
Chen, YS ;
Yu, HY ;
Huang, SC ;
Chiu, KM ;
Lin, TY ;
Lai, LP ;
Lin, FY ;
Wang, SS ;
Chu, SH ;
Ko, WJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (01) :81-87
[3]   Rescue for acute myocarditis with shock by extracorporeal membrane oxygenation [J].
Chen, YS ;
Wang, MJ ;
Chou, NK ;
Han, YY ;
Chiu, IS ;
Lin, FY ;
Chu, SH ;
Ko, WJ .
ANNALS OF THORACIC SURGERY, 1999, 68 (06) :2220-2224
[4]   Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function [J].
Farrar, DJ ;
Holman, WR ;
McBride, LR ;
Kormos, RL ;
Icenogle, TB ;
Hendry, PJ ;
Moore, CH ;
Loisance, DY ;
El-Banayosy, A ;
Frazier, H .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (05) :516-521
[5]   Circulatory support for fulminant myocarditis:: consideration for implantation, weaning and explantation [J].
Leprince, P ;
Combes, A ;
Bonnet, N ;
Ouattara, A ;
Luyt, CE ;
Theodore, P ;
Léger, P ;
Pavie, A .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (03) :399-403
[6]   Transfer of patients receiving advanced mechanical circulatory support [J].
McBride, LR ;
Lowdermilk, GA ;
Fiore, AC ;
Moroney, DA ;
Brannan, JA ;
Swartz, MT .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (05) :1015-1020
[7]   Mechanical circulatory support for acute heart failure [J].
Pennington, DG ;
Smedira, NG ;
Samuels, LE ;
Acker, MA ;
Curtis, JJ ;
Pagani, FD .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S56-S59
[8]   Discussion of acute heart failure [J].
Pennington, DG ;
Acker, MA ;
Curtis, JJ ;
Pagani, FD ;
Samuels, LE ;
Smedira, NG ;
Naka, Y ;
Kormos, RL ;
Savage, EB .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S82-S85
[9]   A new method of monitoring recovery and weaning the thoratec left ventricular assist device [J].
Slaughter, MS ;
Silver, MA ;
Farrar, DJ ;
Tatooles, AJ ;
Pappas, PS .
ANNALS OF THORACIC SURGERY, 2001, 71 (01) :215-218