Which patients benefit from percutaneous mitral balloon valvuloplasty? Prevalvuloplasty and postvalvuloplasty variables that predict long-term outcome

被引:162
作者
Palacios, IF [1 ]
Sanchez, PL [1 ]
Harrell, LC [1 ]
Weyman, AE [1 ]
Block, PC [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Med,Cardiac Unit, Boston, MA 02114 USA
关键词
valvuloplasty; echocardiography; follow-up studies; mitral valve;
D O I
10.1161/01.CIR.0000012143.27196.F4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Percutaneous mitral balloon valvuloplasty (PMV) results in good immediate results, particularly in patients with echocardiographic scores (Echo-Sc) less than or equal to8. However, which variables relate to long-term outcome is unclear. Methods and Results-We report the immediate and long-term clinical follow-up (mean, 4.2 +/- 3.7 years; range, 0.5 to 15) of 879 patients who underwent 939 PMV procedures. Patients were divided into 2 groups, Echo-Sc less than or equal to8 (n=601) and Echo-Sc >8 (n=278). PMV resulted in an increase in mitral valve area from 1.0 +/- 0.3 to 2.0 +/- 0.6 cm(2) in patients with Echo-Sc less than or equal to8 and from 0.8 +/- 3 to 1.6 +/- 6 cm(2) in patients with Echo-Sc >8 (P<0.0001). Although adverse events (death, mitral valve surgery, and redo PMV) were low within the first 5 years of follow-up, a progressive number of events occurred beyond this period. Nevertheless, survival (82% versus 57%) and event-free survival (38% versus 22%) at 12-year follow-up was greater in patients with Echo-Sc >58 (P<0.0001). Cox regression analysis identified post-PMV mitral regurgitation greater than or equal to3+, Echo-Sc >8, age, prior surgical commissurotomy, NYHA functional class IV, pre-PMV mitral regurgitation greater than or equal to2+, and higher post-PMV pulmonary artery pressure as independent predictors of combined events at long-term follow-up. Conclusions-The immediate and long-term outcome of patients undergoing PMV is multifactorial. The use of the Echo-Sc in conjunction with other clinical and morphological predictors of PMV outcome allows identification of patients who will obtain the best outcome from PMV.
引用
收藏
页码:1465 / 1471
页数:7
相关论文
共 36 条
[1]   PREDICTION OF SUCCESSFUL OUTCOME IN 130 PATIENTS UNDERGOING PERCUTANEOUS BALLOON MITRAL VALVOTOMY [J].
ABASCAL, VM ;
WILKINS, GT ;
OSHEA, JP ;
CHOONG, CY ;
PALACIOS, IF ;
THOMAS, JD ;
ROSAS, E ;
NEWELL, JB ;
BLOCK, PC ;
WEYMAN, AE .
CIRCULATION, 1990, 82 (02) :448-456
[2]   ECHOCARDIOGRAPHIC EVALUATION OF MITRAL-VALVE STRUCTURE AND FUNCTION IN PATIENTS FOLLOWED FOR AT LEAST 6 MONTHS AFTER PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY [J].
ABASCAL, VM ;
WILKINS, GT ;
CHOONG, CY ;
THOMAS, JD ;
PALACIOS, IF ;
BLOCK, PC ;
WEYMAN, AE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (03) :606-615
[3]   IMMEDIATE AND LONG-TERM RESULTS OF BALLOON AND SURGICAL CLOSED MITRAL VALVOTOMY - A RANDOMIZED COMPARATIVE-STUDY [J].
ARORA, R ;
NAIR, M ;
KALRA, GS ;
NIGAM, M ;
KHALILULLAH, M .
AMERICAN HEART JOURNAL, 1993, 125 (04) :1091-1094
[4]   Percutaneous balloon versus surgical closed and open mitral commissurotomy - Seven-year follow-up results of a randomized trial [J].
Ben Farhat, M ;
Ayari, M ;
Maatouk, F ;
Betbout, F ;
Gamra, H ;
Jarrar, M ;
Tiss, M ;
Hammami, S ;
Thaalbi, R ;
Addad, F .
CIRCULATION, 1998, 97 (03) :245-250
[5]  
Chen CR, 1998, CATHETER CARDIO DIAG, V43, P132, DOI 10.1002/(SICI)1097-0304(199802)43:2<132::AID-CCD5>3.0.CO
[6]  
2-B
[7]   PREDICTORS OF LONG-TERM OUTCOME AFTER PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY [J].
COHEN, DJ ;
KUNTZ, RE ;
GORDON, SPF ;
PIANA, RN ;
SAFIAN, RD ;
MCKAY, RG ;
BAIM, DS ;
GROSSMAN, W ;
DIVER, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (19) :1329-1335
[8]   BALLOON MITRAL COMMISSUROTOMY AFTER PREVIOUS SURGICAL COMMISSUROTOMY [J].
DAVIDSON, CJ ;
BASHORE, TM ;
MICKEL, M ;
DAVIS, K .
CIRCULATION, 1992, 86 (01) :91-99
[9]   Four-year follow-up of patients undergoing percutaneous balloon mitral commissurotomy - A report from the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry [J].
Dean, LS ;
Mickel, M ;
Bonan, R ;
Holmes, DR ;
ONeill, WW ;
Palacios, IF ;
Rahimtoola, S ;
Slater, JN ;
Davis, K ;
Kennedy, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (06) :1452-1457
[10]  
FELDMAN T, 1994, CATHETER CARDIO DIAG, P26