Multivariate calibration standardization used for the reduction of standards needed for multivariate calibration in inductively coupled plasma mass spectrometry

被引:9
作者
Behrens, A [1 ]
机构
[1] TECH UNIV DENMARK, DEPT CHEM A, DK-2800 LYNGBY, DENMARK
关键词
Gd; ICPMS; multivariate calibration; partial least squares regression (PLS);
D O I
10.1016/S0584-8547(96)01610-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Multivariate calibration methods such as partial least squares regression (PLS) are capable of eliminating spectroscopic interferences in inductively coupled plasma mass spectrometry. These methods often require a large number of standards for the calibration, which can be a drawback if a full recalibration is needed very often. This problem can be circumvented by using multivariate calibration standardization to adjust either the sample or the calibration model to match a given state of the instrument. Four standardization methods (two univariate methods, direct standardization, and inverse model standardization) have been investigated and compared with full and partial calibration. Direct standardization gave the best results. It allowed for up to 78% reduction of the number of standards needed in the daily routine. Inverse model standardization needed more standards to accomplish similar results, and the two univariate methods could not be used for the determination of Gd. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:445 / 458
页数:14
相关论文
共 22 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[3]   Determination of gadolinium in geological samples by inductively coupled plasma mass spectrometry and multivariate calibration [J].
Behrens, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (12) :1521-1530
[4]   MULTIVARIATE CALIBRATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY .2. EFFECT OF CHANGES IN ABUNDANCES OF INTERFERING POLYATOMIC IONS [J].
KETTERER, ME ;
BIDDLE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1819-1823
[5]   MULTIVARIATE CALIBRATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KETTERER, ME ;
RESCHL, JJ ;
PETERS, MJ .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2031-2040
[6]  
KETTERER ME, 1990, ROY SOC CH, V85, P52
[7]   ORTHOGONAL FEATURE SELECTION METHOD [J].
KOWALSKI, BR ;
BENDER, CF .
PATTERN RECOGNITION, 1976, 8 (01) :1-4
[8]   EFFECTS OF OPERATING-CONDITIONS ON THE DETERMINATION OF THE RARE-EARTH ELEMENTS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF ;
KANTIPULY, CJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :75-92
[9]  
NOORD OE, 1994, CHEMOM INTELL LAB SY, V23, P65
[10]   DIRECT STANDARDIZATION IN MULTI WAVELENGTH FLUORESCENCE SPECTROSCOPY [J].
NORGAARD, L .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 29 (02) :283-293