Evaluating the Accuracy of an Aneroid Sphygmomanometer in a Clinical Trial Setting

被引:27
作者
Ma, Yong [1 ]
Temprosa, Marinella [1 ]
Fowler, Sarah [1 ]
Prineas, Ronald J. [2 ]
Montez, Maria G. [3 ]
Brown-Friday, Janet [4 ]
Carrion-Petersen, Mary L. [5 ]
Whittington, Tracy [6 ]
机构
[1] George Washington Univ, Ctr Biostat, Rockville, MD USA
[2] Wake Forest Univ, Bowman Gray Sch Med, Winston Salem, NC 27109 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[4] Albert Einstein Coll Med, Bronx, NY 10467 USA
[5] Univ Calif San Diego, San Diego, CA 92103 USA
[6] Johns Hopkins Univ, Sch Med, Lutherville Timonium, MD USA
关键词
D O I
10.1038/ajh.2008.338
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND The mercury sphygmomanometer, the "gold" standard for blood pressure measurements, has been gradually phased out in many institutions because of environmental concerns, Our on-going clinical trial compared the use of mercury vs. aneroid sphygmomanometers, before implementing a study-wide transition to the aneroid sphygmomanometer. METHODS The Diabetes Prevention Program Outcomes Study (DPPOS) studied the accuracy of the Welch AllynTycos 767-Series Mobile aneroid sphygmomanometer from 20 March 2006 to 21 June 2006 at multiple clinic centers. We compared readings from 997 participants in 24 clinic centers using both mercury and aneroid sphygmomanometers. RESULTS The study found no statistically significant difference for systolic blood pressure (SBP) (P > 0.05) and a small but significantly (P < 0.0001) lower (0.8 mm Hg) reading for diastolic blood pressure (DBP) using the aneroid sphygmomanometer. Regression analysis of aneroid vs. mercury showed regression lines (Y= 4.8 + 0.96Xfor SBR Y= 3.1 + 0.95X for DBP) slightly but statistically significantly different from the line of equality (P < 0,001). Participants' age, sex, race/ethnicity, body mass index, blood pressure, and clinical center together explain about 8-10% of the variation of the difference between readings from the two sphygmomanometers. Based on the above result, on I August 2006, DPPOS clinics began the conversion from mercury to aneroid sphygmomanometers. CONCLUSIONS The Welch Allyn Tycos 767-Series Mobile Aneroid model 7670-04 tested in this validation study can be used to replace mercury model in clinical trials.
引用
收藏
页码:263 / 266
页数:4
相关论文
共 10 条
[1]   ANEROID SPHYGMOMANOMETERS - AN ASSESSMENT OF ACCURACY AT A UNIVERSITY HOSPITAL AND CLINICS [J].
BAILEY, RH ;
KNAUS, VL ;
BAUER, JH .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (07) :1409-1412
[2]  
Bray GA, 1999, DIABETES CARE, V22, P623
[3]   Are aneroid sphygmomanometers accurate in hospital and clinic settings? [J].
Canzanello, VJ ;
Jensen, PL ;
Schwartz, GL .
ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (05) :729-731
[4]   Hypertension, insulin, and proinsulin in participants with. impaired glucose tolerance [J].
Haffner, SM ;
Goldberg, R ;
Ratner, R ;
Lachin, J ;
Temprosa, M ;
Orchard, T ;
Molitch, M ;
Saad, M .
HYPERTENSION, 2002, 40 (05) :679-686
[5]   Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin [J].
Knowler, WC ;
Barrett-Connor, E ;
Fowler, SE ;
Hamman, RF ;
Lachin, JM ;
Walker, EA ;
Nathan, DM .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (06) :393-403
[6]  
Latman Neal S., 1998, Biomedical Instrumentation and Technology, V32, P282
[7]  
MESSELBECK J, 1999, DIABETES CARE, V22, P623
[8]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[9]   Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experience [J].
Yarows, SA ;
Qian, K .
BLOOD PRESSURE MONITORING, 2001, 6 (02) :101-106
[10]  
1908, BIOMETRIKA, V6, P1