A micro-scale mercury cathode electrolysis procedure for on-line flow injection inductively coupled plasma mass spectrometry trace elements analysis in steel samples

被引:14
作者
Coedo, AG [1 ]
Padilla, I [1 ]
Dorado, T [1 ]
Alguacil, FJ [1 ]
机构
[1] CSIC, Ctr Nacl Invest Met, E-28040 Madrid, Spain
关键词
matrix removal; a micro-scale electrolysis cell; trace elements; steel samples; FI-ICP-MS;
D O I
10.1016/S0003-2670(99)00125-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line matrix-analyte separation technique was developed for flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) trace analysis. A micro electrolytic cell was designed to be inserted in the FI manifold. The technique was used to separate Zr, Hf, Y, rare earth elements (REEs), Th and U from a steel-matrix (Fe, Cr, Ni, Co, Mn and Mo). A microwave-assisted HNO3-HCl-HF-H2SO4 digestion procedure, with temperature/pressure regulation, was used for sample dissolution. Obtained solutions were evaporated to SO3 fumes, and 2 mi of this diluted sulphuric solution were introduced in the electrolytic cell through the manifold circuit. After matrix removal, the electrolyte was conducted to load a 300 mu l sample loop to be injected into the plasma torch. Direct multielement standard solutions in diluted sulphuric acid (without matrix matching and sample pretreatment) were applied for external calibration. The determination limits, with reference to the solid, were improved by a factor of about 10 compared with that obtained from direct measurements of 0.1% (m/v) sample solutions. The relative standard deviations for all the analytes were better than 3.5% for concentrations above 10 times the limit of quantification. The developed method was applied in the determination of certified elements in Steel Reference Materials: NIST 363 and NIST 364. Recoveries from 0.200 g test portions of high-purity iron spiked at two different concentration levels were found better than 97%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 23 条
[1]  
*BRIT STAND I, 1955, BRIT STAND 1121 C ME
[2]  
*BRIT STAND I, 1970, BS HDB, V19
[3]   Study of the application of air-water flow injection inductively coupled plasma mass spectrometry for the determination of calcium in steels [J].
Coedo, AG ;
Dorado, MT ;
Padilla, I ;
Alguacil, FJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1037-1041
[4]   ONLINE ION-EXCHANGE SEPARATION AND DETERMINATION OF NIOBIUM, TANTALUM, TUNGSTEN, ZIRCONIUM AND HAFNIUM IN HIGH-PURITY IRON BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
COEDO, AG ;
LOPEZ, TD ;
ALGUACIL, F .
ANALYTICA CHIMICA ACTA, 1995, 315 (03) :331-338
[5]   DETERMINATION OF TRACE-ELEMENTS IN UNALLOYED STEELS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
COEDO, AG ;
DORADO, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (06) :449-453
[6]   Determination of phosphorus content in steels using flow injection into an argon-water carrier for Inductively Coupled Plasma Mass Spectrometry [J].
Coedo, AG ;
Dorado, T ;
Padilla, I ;
Alguacil, FJ .
ISIJ INTERNATIONAL, 1997, 37 (09) :878-884
[7]  
COEDO AG, 1998, 18207 CECAEUR, P146
[8]  
CRIGHTON J, 1996, J ANAL ATOM SPECTROM, V11, pR462
[9]  
DORADO MT, 1978, METALURGIJA, P37
[10]  
DUVAL C, 1955, TRAITE MICRO ANAL MI, V2, P11