Estimating the Capacity Value of Concentrating Solar Power Plants With Thermal Energy Storage: A Case Study of the Southwestern United States

被引:80
作者
Madaeni, Seyed Hossein [1 ]
Sioshansi, Ramteen [1 ]
Denholm, Paul [2 ]
机构
[1] Ohio State Univ, Integrated Syst Engn Dept, Columbus, OH 43210 USA
[2] Natl Renewable Energy Lab, Strateg Energy Anal Ctr, Golden, CO 80401 USA
关键词
Capacity value; concentrating solar power; equivalent conventional power; LOAD-CARRYING CAPABILITY; WIND POWER; SYSTEM;
D O I
10.1109/TPWRS.2012.2207410
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We estimate the capacity value of concentrating solar power (CSP) plants with thermal energy storage (TES) in the southwestern U. S. Our results show that incorporating TES in CSP plants significantly increases their capacity value. While CSP plants without TES have capacity values ranging between 60% and 86% of maximum capacity, plants with TES can have capacity values between 79% and 92%. We demonstrate the effect of location and configuration on the operation and capacity value of CSP plants. We also show that using a capacity payment mechanism can increase the capacity value of CSP, since the capacity value of CSP is highly sensitive to operational decisions and energy prices are not a perfect indicator of scarcity of supply.
引用
收藏
页码:1205 / 1215
页数:11
相关论文
共 45 条
[1]   Comparison of Capacity Credit Calculation Methods for Conventional Power Plants and Wind Power [J].
Amelin, Mikael .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (02) :685-691
[2]  
[Anonymous], 2003, NRELSR55034440
[3]  
[Anonymous], DOEGO1020082567
[4]  
[Anonymous], NRELCP44022591
[5]  
[Anonymous], 1991, NATL SOLAR RAD DATAB
[6]   Development of a high-temperature long-shafted, molten-salt pump for power tower applications [J].
Barth, DL ;
Pacheco, JE ;
Kolb, WJ ;
Rush, EE .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02) :170-175
[7]  
Bernow S., 1994, ORNLSUB9303370
[8]  
Billinton R., 1984, Reliability Evaluation of Power Systems, DOI DOI 10.1007/978-1-4899-1286-213#
[9]   Noniterative method to approximate the effective load carrying capability of a wind plant [J].
D'Annunzio, Claudine ;
Santoso, Surya .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) :544-550
[10]   The value of compressed air energy storage with wind in transmission-constrained electric power systems [J].
Denholm, Paul ;
Sioshansi, Ramteen .