A new system for three-dimensional gait recording using electromagnetic tracking

被引:23
作者
Kobayashi, K
Gransberg, L
Knutsson, E
Nolen, P
机构
[1] KAROLINSKA HOSP, DEPT CLIN NEUROPHYSIOL, S-17176 STOCKHOLM, SWEDEN
[2] JIKEI UNIV, SCH MED, DEPT REHABIL MED, TOKYO, JAPAN
关键词
gait analysis; three-dimensional kinematics; electromagnetic tracking;
D O I
10.1016/S0966-6362(96)01102-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A new methodology for three-dimensional gait recording was tested. It was based upon an electromagnetic tracking instrument. It repeatedly generates three different magnetic fields from orthogonal coils in a transmitter. A sensor in these fields measures the magnetic flux in three orthogonal coils. From the resulting nine signals of magnetic flux, sensor position in x, y and z coordinates, and orientation in sagittal, coronal and transverse planes can be obtained. The errors in records of position and orientation were determined from recordings with a sensor in a series of well-defined positions within an area sufficiently large to record the movements of a stride. Due to environmental disturbances of the generated magnetic fields, the errors were too large to allow relevant recordings of gait movements. After compensation for the local environmental disturbances, the errors of x, y and z coordinates were < 2.0 cm, and the error of angle in the sagittal, coronal and transverse planes < 1.0 degree. Measurements of rotations with the sensor in unchanged position had an error < 2.5%. With four sensors fixed to pelvis and leg segments, records of three-dimensional gait movements were obtained viith well-defined precision in all dimensions. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 26 条
[1]  
BIDEN E, 1990, LIGAMENTS STRUCTURE, P291
[2]  
Chao E.Y., 1978, CRC HDB ENG MED BIOL, V1, P385
[3]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[4]   JUSTIFICATION OF TRIAXIAL GONIOMETER FOR THE MEASUREMENT OF JOINT ROTATION [J].
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1980, 13 (12) :989-+
[5]  
HARRIS GF, 1994, ARCH PHYS MED REHAB, V75, P216
[6]   BIOMECHANICAL COMPARISON BETWEEN HIGH TIBIAL OSTEOTOMY (HTO) AND COMBINED HTO AND FIBULAR OSTEOTOMY [J].
HEFZY, MS ;
SADDEMI, SR ;
CHENG, G ;
HOEFLINGER, M ;
MILEM, C ;
FROGAMENI, AD .
CLINICAL BIOMECHANICS, 1994, 9 (05) :284-290
[7]   EFFECTS OF TIBIAL ROTATIONS ON PATELLAR TRACKING AND PATELLOFEMORAL CONTACT AREAS [J].
HEFZY, MS ;
JACKSON, WT ;
SADDEMI, SR ;
HSIEH, YF .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (04) :329-343
[8]   3-DIMENSIONAL ELECTROGONIOMETRIC GAIT RECORDING [J].
ISACSON, J ;
GRANSBERG, L ;
KNUTSSON, E .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :627-&
[9]  
JOHANSON ME, 1994, HUMAN WALKING, P201
[10]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860