Morphometrical measurements of resected surface of femurs in Chinese knees: Correlation to the sizing of current femoral implants

被引:101
作者
Ho, WP
Cheng, CK
Liau, HJ
机构
[1] United Orthoped Corp, Dept Res & Dev, Taipei 235, Taiwan
[2] Taipei Med Univ, Wan Fang Hosp, Dept Orthopaed Surg, Taipei, Taiwan
关键词
morphometrical measurement; resected femur; knee dimensions; total knee arthroplasty;
D O I
10.1016/j.knee.2005.05.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Morphometrical data were measured in the resected femurs of seventy Chinese patients who underwent total knee arthroplasties. Two measured parameters, the anterior-posterior length of the lateral condyle and the total width of the distal condyle, were compared to the anterior-posterior length and the medial-lateral width of five femoral implants currently used in Taiwan. Three implants (Duracon, NexGen and UKnee) have a larger medial-lateral width than the total width of the resected distal condyle for a given femoral implant anterior-posterior length. These implants tend to overhang the medial-lateral width of resected femurs from Chinese patients. In addition, one femoral implant (Duracon), which has previously been shown to be suitable for use in Caucasian patients, is not suitable in Chinese patients. Our results will allow manufacturers to design femoral implants better suited to Chinese patients. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 14
页数:3
相关论文
共 13 条
[1]
A new approach of designing the tibial baseplate of total knee prostheses [J].
Cheng, CK ;
Lung, CY ;
Lee, YM ;
Huang, CH .
CLINICAL BIOMECHANICS, 1999, 14 (02) :112-117
[2]
CHOW SL, 1996, THESIS NANYANG TU
[3]
DORR LD, 1986, CLIN ORTHOP RELAT R, P5
[4]
Anthropometric measurements of the human knee: Correlation to the sizing of current knee arthroplasty systems [J].
Hitt, K ;
Shurman, JR ;
Greene, K ;
McCarthy, J ;
Moskal, J ;
Hoeman, T ;
Mont, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :115-122
[5]
HUANG CH, 2000, J MUSCULOSKELET RES, V4, P39, DOI DOI 10.1142/S0218957700000069
[6]
LIU HC, 1984, J FORMOS MED ASSOC, V83, P317
[7]
Determination of the major dimensions of femoral implants using morphometrical data and principal component analysis [J].
Low, FH ;
Khoo, LP ;
Chua, CK ;
Lo, NN .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H3) :301-309
[8]
Matsuda S, 1998, CLIN ORTHOP RELAT R, P183
[9]
MENSCH JS, 1975, CLIN ORTHOP RELAT R, P231
[10]
Urabe Ken, 2003, J Knee Surg, V16, P27