Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source

被引:14
作者
Chao, Bing-Fong [1 ]
Chen, Chao-Jung [1 ]
Li, Fu-An [1 ]
Her, Guor-Rong [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 106, Taiwan
关键词
capillary zone electrophoresis; mass spectrometry; pulsed spray; sheathless interface;
D O I
10.1002/elps.200500811
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sheathless interface has been developed for coupling CE with electrospray IT mass spectrometer. This interface utilized a pulsed ESI source. The use of a pulsed electrospray source allows the use of a sprayer with larger orifice, and thus alleviates the problem of column clogging during conductive coating and CE analysis. A pulsed ESI source operated at 20 Hz and 20% duty cycle was found to produce the optimal signals. For better signals, the maximum ion injection time in the IT mass spectrometer has to be set to a value close to the actual spraying time (10 ms). Using a sprayer with 50 mu m od, more stable and enhanced signals were obtained in comparison with continuous CE-ESI-MS under the same flow rate (150 nL/min). The utility of this design is demonstrated with the analysis of synthetic drugs by CE-MS.
引用
收藏
页码:2083 / 2090
页数:8
相关论文
共 37 条
[1]  
Barroso MB, 1999, J AM SOC MASS SPECTR, V10, P1271
[2]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[3]   Single-pulse nanoelectrospray ionization [J].
Berggren, WT ;
Westphall, MS ;
Smith, LM .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3443-3448
[4]   Pressure-assisted and pressure-programmed capillary electrophoresis/electrospray ionization time of flight - mass spectrometry for the analysis of peptide mixtures [J].
Cao, P ;
Moini, M .
ELECTROPHORESIS, 1998, 19 (12) :2200-2206
[5]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge [J].
Chang, YZ ;
Chen, YR ;
Her, GR .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5083-5087
[6]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary [J].
Chang, YZ ;
Her, GR .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :626-630
[7]   A simple method for fabrication of silver-coated sheathless electrospray emitters [J].
Chen, YR ;
Her, GR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (05) :437-441
[8]   Fritless capillary columns for HPLC and CEC prepared by immobilizing the stationary phase in an organic polymer matrix [J].
Chirica, GS ;
Remcho, VT .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3605-3610
[9]   Affinity capillary electrophoresis mass spectrometry for screening combinatorial libraries [J].
Chu, YH ;
Dunayevskiy, YM ;
Kirby, DP ;
Vouros, P ;
Karger, BL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (33) :7827-7835
[10]   Advances in CE MS [J].
Ding, JM ;
Vouros, P .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :378A-385A