Potential hazards of deionization systems used for water purification in hemodialysis

被引:17
作者
Bland, LA
Arnow, PM
Arduino, MJ
Bova, J
McAllister, SK
机构
[1] CTR DIS CONTROL & PREVENT,DIALYSIS & MED DEVICES SECT C01,HOSP INFECT PROGRAM,ATLANTA,GA 30333
[2] UNIV CHICAGO HOSP,INFECT CONTROL PROGRAM,CHICAGO,IL
[3] UNIV CHICAGO HOSP,DEPT MED,CHICAGO,IL
关键词
hemodialysis; water purification; deionization;
D O I
10.1111/j.1525-1594.1996.tb04411.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was conducted to determine the efflux of specific ions, including fluoride, from a deionization (DI) water purification system (WPS) when the WPS was operated beyond exhaustion of the DI resin. Effluent from the DI WPS was monitored for resistivity, total dissolved solids, pH, and concentrations of silica, fluoride, potassium, and sodium. After 16,000 L of water was purified, the resistivity declined to 0.492 Omega Ohm-cm, and silica was released from the DI WPS. Fluoride ions were released after an additional 8,000 L water was treated, and the resistivity fell to 0.07 Omega Ohm-cm. The fluoride efflux reached a peak of 32 mg/L, 28 times greater than the original fluoride concentration in the city water. Sodium and potassium ions were released after approximately 26,000 and 32,000 L, of water had been treated and reached peaks of 76 and 47 mg/L, respectively. This study confirms that the minimum resistivity standard of 1 Omega Ohm-cm for DI water used for hemodialysis should provide an adequate safety margin. Once resistivity fell to 1 Omega Ohm-cm, more than 8,000 L of water was treated before fluoride efflux occurred. Accordingly, hemodialysis centers should be attentive to the calculated capacity of their DI WPS and reliably monitor the resistivity to prevent patient illness related to exhaustion of DI resins.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 23 条
[1]  
Arduino MJ, 1989, DIALYSIS TRANSPLANT, V18, P655
[2]   AN OUTBREAK OF FATAL FLUORIDE INTOXICATION IN A LONG-TERM HEMODIALYSIS UNIT [J].
ARNOW, PM ;
BLAND, LA ;
GARCIAHOUCHINS, S ;
FRIDKIN, S ;
FELLNER, SK .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (05) :339-344
[3]  
Bailey P.L., 1980, ANAL ION SELECTIVE E
[4]  
BELLACK E, 1968, ANAL CHEM, V30, P2032
[5]  
Bunting W.E., 1944, IND ENG CHEM ANAL ED, V16, P612, DOI DOI 10.1021/I560134A006
[6]  
Clifford D. A., 1990, WATER QUALITY TREATM, P561
[7]  
FAVERO MS, 1987, RENALIFE, V2, P14
[8]   ENVIRONMENTAL AND IATROGENIC OBSTACLES TO LONG LIFE ON HEMODIALYSIS [J].
FRIEDMAN, EA ;
LUNDIN, AP .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 306 (03) :167-169
[9]  
IVANOVICH P, 1969, T AM SOC ART INT ORG, V15, P316
[10]   EXPOSURE TO EXCESSIVE FLUORIDE DURING HEMODIALYSIS [J].
JOHNSON, WJ ;
TAVES, DR .
KIDNEY INTERNATIONAL, 1974, 5 (06) :451-454