Quantitative Analysis of the Parameters Affecting In-Cabin to On-Roadway (I/O) Ultrafine Particle Concentration Ratios

被引:49
作者
Xu, Bin [1 ]
Zhu, Yifang [1 ]
机构
[1] Texas A&M Univ, Dept Environm Engn, Kingsville, TX 78363 USA
基金
美国国家科学基金会;
关键词
AIR; PENETRATION; EXPOSURE; TRANSLOCATION; DISTRIBUTIONS; DEPOSITION; NUMBER; RATES;
D O I
10.1080/02786820802705837
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A mass-balance indoor particle dynamic model was adopted and modified to investigate how on-roadway ultrafine particle (UFP, diameter < 100 nm) concentrations and vehicle ventilation settings affect UFP levels inside vehicles. The model was first parameterized focusing on a mechanistic, simulation-based interpretation of in-cabin data reported in Zhu et al. (2007). Under three different ventilation conditions, (1) Fan off-recirculation (RC) off, (2) Fan on-RC off, and (3) Fan on-RC on, the modeled UFP incabin to on-roadway (I/O) ratios were found to be 0.40, 0.25, and 0.10, respectively, and agree with the experimental data very well. Then, analysis focused on how the model input parameters, such as ventilation settings, vehicle speed, filtration, penetration, deposition, and human respiration, affect I/O ratios in broader categories of vehicle cabin microenvironments. Under condition (1), the modeled I/O ratios increased linearly, up to similar to 25%, within the literature reported penetration factor range. The I/O ratios were directly proportional to vehicle speeds and inversely affected by deposition coefficients. Under condition (2), the airflow rate of mechanical ventilation was the predominant factor and I/O ratio was inversely proportional to the airflow rate in the range of 0-108 m(3)/h(-1), and directly proportional to the airflow rate in the range of 108-360 m(3)/h(-1). Under condition (3), the effects of penetration factor, deposition coefficient, and vehicle speed were comparable. The modeled I/O ratio was inversely proportional to the airflow rate from mechanical ventilation in the whole range (0-360 m(3) h(-1)) with 10-20% influence depending on the particle size.
引用
收藏
页码:400 / 410
页数:11
相关论文
共 26 条
[1]   AIR-FLOW THROUGH CRACKS [J].
BAKER, PH ;
SHARPLES, S ;
WARD, IC .
BUILDING AND ENVIRONMENT, 1987, 22 (04) :293-304
[2]   Indoor-outdoor air quality relationships in vehicle: effect of driving environment and ventilation modes [J].
Chan, AT ;
Chung, MW .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (27) :3795-3808
[3]  
GONG L, 2009, AEROSOL SCI IN PRESS
[4]   On-road measurements of particle number concentrations and size distributions in urban and tunnel environments [J].
Gouriou, F ;
Morin, JP ;
Weill, ME .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (18) :2831-2840
[5]  
Hinds W. C., 1999, AEROSOL TECHNOLOGY P, DOI 10.1016/0021-8502(83)90049-6
[6]   Exposure visualisation of ultrafine particle counts in a transport microenvironment [J].
Kaur, S ;
Clark, RDR ;
Walsh, PT ;
Arnold, SJ ;
Colvile, RN ;
Nieuwenhuijsen, M .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (02) :386-398
[7]   Roadside and in-vehicle concentrations of monoaromatic hydrocarbons [J].
Leung, PL ;
Harrison, RM .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (02) :191-204
[8]   Particle penetration through building cracks [J].
Liu, DL ;
Nazaroff, WW .
AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (07) :565-573
[9]   Modeling pollutant penetration across building envelopes [J].
Liu, DL ;
Nazaroff, WW .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (26) :4451-4462
[10]   RESIDENTIAL AIR EXCHANGE-RATES IN THE UNITED-STATES - EMPIRICAL AND ESTIMATED PARAMETRIC DISTRIBUTIONS BY SEASON AND CLIMATIC REGION [J].
MURRAY, DM ;
BURMASTER, DE .
RISK ANALYSIS, 1995, 15 (04) :459-465