Bioresorbable scaffolds: Current knowledge, potentialities and limitations experienced during their first clinical applications

被引:67
作者
Bourantas, Christos V. [1 ]
Onuma, Yoshinobu [1 ]
Farooq, Vasim [1 ]
Zhang, Yaojun [1 ]
Garcia-Garcia, Hector M. [1 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
关键词
Bioresorbable scaffolds; Drug eluting stents; Coronary artery disease; OPTICAL COHERENCE TOMOGRAPHY; ELUTING VASCULAR SCAFFOLD; ACID CORONARY STENTS; BARE METAL STENT; SHEAR-STRESS; PERCUTANEOUS CORONARY; ARTERIAL-WALL; FOLLOW-UP; IMPLANTATION; REVASCULARIZATION;
D O I
10.1016/j.ijcard.2012.05.093
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The traditional metallic stents have significant limitations as they predispose to late thrombosis, may preclude surgical revascularization and distort vessel physiology. Bioresorbable scaffolds (BRSs) are a relatively new technology introduced to overcome these drawbacks. The potential of these devices as well as the reported results from their clinical applications attracted interest and drove research and industry towards the development of new BRSs and the improvement of the existing devices. Thus, over the last years considerable progress has been made and today numerous BRSs are available. The aim of this review article is to highlight the potentialities of these devices, describe the evidence from the recent clinical trials and discuss the advantages, limitations and concerns that were aroused during the first implementation of BRSs in clinical arena. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:11 / 21
页数:11
相关论文
共 67 条
[1]
Angiographic and clinical outcome following coronary stenting of small vessels - A comparison with coronary stenting of large vessels [J].
Akiyama, T ;
Moussa, I ;
Reimers, B ;
Ferraro, M ;
Kobayashi, Y ;
Blengino, S ;
Di Francesco, L ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) :1610-1618
[2]
Coronary artery stents [J].
Al Suwaidi, J ;
Berger, PB ;
Holmes, DR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 284 (14) :1828-1836
[3]
An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[4]
Biamino G, 2005, J ENDOVASC THER, V12, P5
[5]
Circumferential evaluation of the neointima by optical coherence tomography after ABSORB bioresorbable vascular scaffold implantation: Can the scaffold cap the plaque? [J].
Brugaletta, Salvatore ;
Radu, Maria D. ;
Garcia-Garcia, Hector M. ;
Heo, Jung Ho ;
Farooq, Vasim ;
Girasis, Chrysafios ;
van Geuns, Robert-Jan ;
Thuesen, Leif ;
McClean, Dougal ;
Chevalier, Bernard ;
Windecker, Stephan ;
Koolen, Jacques ;
Rapoza, Richard ;
Miquel-Hebert, Karine ;
Ormiston, John ;
Serruys, Patrick W. .
ATHEROSCLEROSIS, 2012, 221 (01) :106-112
[6]
Two-Year Clinical, Angiographic, and Intravascular Ultrasound Follow-Up of the XIENCE V Everolimus-Eluting Stent in the Treatment of Patients With De Novo Native Coronary Artery Lesions The SPIRIT II Trial [J].
Claessen, Bimmer E. ;
Beijk, Marcel A. ;
Legrand, Victor ;
Ruzyllo, Witold ;
Manari, Antonio ;
Varenne, Olivier ;
Suttorp, Maarten J. ;
Tijssen, Jan G. P. ;
Miquel-Hebert, Karine ;
Veldhof, Susan ;
Henriques, Jose P. S. ;
Serruys, Patrick W. ;
Piek, Jan J. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) :339-347
[7]
6-Month Clinical Outcomes Following Implantation of the Bioresorbable Everolimus-Eluting Vascular Scaffold in Vessels Smaller or Larger Than 2.5 mm [J].
Diletti, Roberto ;
Onuma, Yoshinobu ;
Farooq, Vasim ;
Gomez-Lara, Josep ;
Brugaletta, Salvatore ;
van Geuns, Robert Jan ;
Regar, Evelyn ;
de Bruyne, Bernard ;
Dudek, Dariusz ;
Thuesen, Leif ;
Chevalier, Bernard ;
McClean, Dougal ;
Windecker, Stephan ;
Whitbourn, Robert ;
Smits, Pieter ;
Koolen, Jacques ;
Meredith, Ian ;
Li, Dong ;
Veldhof, Susan ;
Rapoza, Richard ;
Garcia-Garcia, Hector M. ;
Ormiston, John A. ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (03) :258-264
[8]
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial [J].
Erbel, Raimund ;
Di Mario, Carlo ;
Bartunek, Jozef ;
Bonnier, Johann ;
de Bruyne, Bernard ;
Eberli, Franz R. ;
Erne, Paul ;
Haude, Michael ;
Heublein, Bernd ;
Horrigan, Mark ;
Ilsley, Charles ;
Boese, Dirk ;
Koolen, Jacques ;
Luescher, Thomas F. ;
Weissman, Neil ;
Waksman, Ron .
LANCET, 2007, 369 (9576) :1869-1875
[9]
Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[10]
Proximal and distal maximal luminal diameters as a guide to appropriate deployment of the ABSORB everolimus-eluting bioresorbable vascular scaffold: A Sub-Study of the ABSORB Cohort B and the On-Going ABSORB EXTEND Single Arm Study [J].
Farooq, Vasim ;
Gomez-Lara, Josep ;
Brugaletta, Salvatore ;
Gogas, Bill D. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
van Geuns, Robert Jan ;
Bartorelli, Antonio ;
Whitbourn, Robert ;
Abizaid, Alexandre ;
Serruys, Patrick W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (06) :880-888