Long- and Short-Term Temporal Stability of Complex Fractionated Atrial Electrograms in Human Left Atrium During Atrial Fibrillation

被引:29
作者
Scherr, Daniel [2 ,3 ]
Dalal, Darshan [2 ]
Cheema, Aamir [2 ]
Nazarian, Saman [2 ]
Almasry, Ibrahim [2 ]
Bilchick, Kenneth [2 ]
Cheng, Alan [2 ]
Henrikson, Charles A. [2 ]
Spragg, David [2 ]
Marine, Joseph E. [2 ]
Berger, Ronald D. [2 ]
Calkins, Hugh [2 ]
Dong, Jun [1 ,2 ]
机构
[1] US FDA, Div Cardiovasc Devices, Ctr Devices & Radiol Hlth, Rockville, MD 20850 USA
[2] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
[3] Med Univ Graz, Dept Med, Div Cardiol, Graz, Austria
基金
奥地利科学基金会;
关键词
atrial fibrillation; complex atrial electrogram; atrium; mapping; ablation; CATHETER ABLATION; AUTOMATED DETECTION; SUBSTRATE ABLATION; PULMONARY VEINS; TERMINATION; SITES; HEART;
D O I
10.1111/j.1540-8167.2008.01278.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Complex fractionated atrial electrograms (CFAEs) have been reported as targets for catheter ablation of atrial fibrillation (AF). However, the temporal stability of CFAE sites remains poorly defined. Methods and Results: The study consisted of two phases. In the initial phase, two automated software algorithms, namely the interval confidence level (ICL) and the average interpotential interval (AIPI) were assessed for their diagnostic accuracy for automated CFAE detection. The AIPI was found to be superior to the ICL, and an AIPI of <= 100 ms was associated with a sensitivity and specificity of both 92% for detection of CFAEs. In the second phase of the study, 12 patients (2 females, mean age 54 +/- 12 years) who underwent catheter ablation for persistent AF were studied to investigate the temporal stability of CFAEs. Two consecutive left atrial (LA) three-dimensional CFAE maps coded with AIPI readings were reconstructed during ongoing AF in each study patient, with a mean time difference of 34.3 +/- 8.7 minutes between the two maps. Among a total of 149 CFAE sites and 238 non-CFAE sites on the first CFAE map that were precisely revisited during the repeat mapping process, 135 (90.6%) and 225 (94.5%) remained as CFAE sites and non-CFAE sites, respectively. RF ablation at the selected stable CFAE sites significantly prolonged AF cycle length (181 +/- 26 ms to 199 +/- 29 ms, P < 0.0001). Conclusion: CFAEs recorded in the LA during AF display high temporal stability in patients with persistent AF. The clinical significance of our findings warrants further investigation. (J Cardiovasc Electrophysiol, Vol. 20, pp. 13-21, January 2009).
引用
收藏
页码:13 / 21
页数:9
相关论文
共 30 条
[1]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[2]   Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation [J].
Dong, J ;
Dickfeld, T ;
Dalal, D ;
Cheema, A ;
Vasamreddy, CR ;
Henrikson, CA ;
Marine, JE ;
Halperin, HR ;
Berger, RD ;
Lima, JAC ;
Bluemke, DA ;
Calkins, H .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (05) :459-466
[3]   ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
CIRCULATION, 2006, 114 (07) :E257-E354
[4]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[5]   Catheter ablation of long-lasting persistent atrial fibrillation:: Critical structures for termination [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Takahashi, Y ;
Rotter, M ;
Sacher, F ;
Rostock, T ;
Hsu, LF ;
Bordachar, P ;
Reuter, S ;
Roudaut, R ;
Clémenty, J ;
Jaïs, P .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (11) :1125-1137
[6]   Changes in atrial fibrillation cycle length and inducibility during catheter ablation and their relation to outcome [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Hsu, LF ;
Shah, DC ;
Scavée, C ;
Takahashi, Y ;
Rotter, M ;
Pasquié, JL ;
Garrigue, S ;
Clémenty, J ;
Jaïs, P .
CIRCULATION, 2004, 109 (24) :3007-3013
[7]   Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation [J].
Jalife, J ;
Berenfeld, O ;
Mansour, M .
CARDIOVASCULAR RESEARCH, 2002, 54 (02) :204-216
[8]   Electrophysiology at a crossroads - Creative concepts [J].
Josephson, Mark E. .
HEART RHYTHM, 2007, 4 (05) :658-661
[9]  
Konings KTS, 1997, CIRCULATION, V95, P1231
[10]   HIGH-DENSITY MAPPING OF ELECTRICALLY-INDUCED ATRIAL-FIBRILLATION IN HUMANS [J].
KONINGS, KTS ;
KIRCHHOF, CJHJ ;
SMEETS, JRLM ;
WELLENS, HJJ ;
PENN, OC ;
ALLESSIE, MA .
CIRCULATION, 1994, 89 (04) :1665-1680