New enzyme sensors for morphine and codeine based on morphine dehydrogenase and laccase

被引:59
作者
Bauer, CG
Kühn, A
Gajovic, N
Skorobogatko, O
Holt, PJ
Bruce, NC
Makower, AA
Lowe, CR
Scheller, FW
机构
[1] Univ Potsdam, Inst Biochem & Mol Physiol, D-14943 Luckenwalde, Germany
[2] Univ Cambridge, Inst Biotechnol, Cambridge CB2 1QT, England
[3] Russian Acad Sci, AN Bach Inst Biochem, Moscow 117071, Russia
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 1-2期
关键词
D O I
10.1007/s002160051320
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two new enzymatic methods have been developed to quantify morphine and codeine simultaneously in a flow injection system (FIA). The first enzyme sensor for morphine or codeine is based on immobilizing morphine dehydrogenase (MDH) and salicylate hydroxylase (SHL) on top of a Clark-type oxygen electrode. Morphine or codeine oxidation by MDH leads to a consumption of oxygen by SHL via the production of NADPH. This decreases the oxygen current of the Clark electrode. Concentrations of codeine and morphine are detected between 2 and 1000 mu M and between 5 and 1000 mu M, respectively. The second enzyme sensor for morphine is based on laccase (LACC) and PQQ-dependent glucose dehydrogenase (GDH) immobilized at a Clark oxygen electrode. Morphine is oxidized by laccase under consumption of oxygen and regenerated by glucose dehydrogenase. Since laccase cannot oxidize codeine, this sensor is selective for morphine. Morphine is detected between 32 nM and 100 mu M. Both sensors can be operated simultaneously in one flow system (FIA) giving two signals without the requirement for a separation step. This rapid and technically simple method allows discrimination between morphine and codeine in less than 1 min after injection. The sampling rate for quantitative measurements is 20 h(-1). The method has been applied to the quantitative analysis of codeine or morphine in drugs.
引用
收藏
页码:179 / 183
页数:5
相关论文
共 25 条
[1]   Enzyme-linked immunosorbent assay and latex agglutination inhibition reaction test for morphine in urine [J].
Aoki, K ;
Shikama, Y ;
Kokado, A ;
Yoshida, T ;
Kuroiwa, Y .
FORENSIC SCIENCE INTERNATIONAL, 1996, 81 (2-3) :125-132
[2]  
Barnett NW, 1996, FRESEN J ANAL CHEM, V355, P591
[3]   Determination of codeine in process streams using flow-injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Bowser, TA ;
Gerardi, RD ;
Smith, B .
ANALYTICA CHIMICA ACTA, 1996, 318 (03) :309-317
[4]   THE STRUCTURE OF PSEUDOMORPHINE [J].
BENTLEY, KW ;
DYKE, SF .
JOURNAL OF THE CHEMICAL SOCIETY, 1959, (JUL-A) :2574-2577
[5]   MICROBIAL-DEGRADATION OF THE MORPHINE ALKALOIDS - PURIFICATION AND CHARACTERIZATION OF MORPHINE DEHYDROGENASE FROM PSEUDOMONAS-PUTIDA M10 [J].
BRUCE, NC ;
WILMOT, CJ ;
JORDAN, KN ;
STEPHENS, LDG ;
LOWE, CR .
BIOCHEMICAL JOURNAL, 1991, 274 :875-880
[6]   MICROBIAL-DEGRADATION OF THE MORPHINE ALKALOIDS - IDENTIFICATION OF MORPHINONE AS AN INTERMEDIATE IN THE METABOLISM OF MORPHINE BY PSEUDOMONAS-PUTIDA M10 [J].
BRUCE, NC ;
WILMOT, CJ ;
JORDAN, KN ;
TREBILCOCK, AE ;
STEPHENS, LDG ;
LOWE, CR .
ARCHIVES OF MICROBIOLOGY, 1990, 154 (05) :465-470
[7]  
BRUCE NC, 1993, BIOCHEM J, V299, P805
[8]   AUTOMATED KINETIC SPECTROFLUOROMETRIC METHOD FOR THE DETERMINATION OF MORPHINE IN URINE [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYST, 1993, 118 (07) :923-927
[9]  
CHEN P, 1994, RES COMMUN SUBSTANCE, V15, P71
[10]   ESTIMATION OF OPIATES IN URINE BY STOPPED-FLOW FLUOROIMMUNOASSAY [J].
GAIKWAD, A ;
GOMEZHENS, A ;
PEREZBENDITO, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :450-453